Operating instructions

Rexroth IndraDrive Mounting and Installation 6-49
DOK-INDRV*-FU*********-IB01-EN-P
HCS02.1N-W0012, -W0028, -W0054, -W0070:
Cross section
single-wire
[mm²]
Cross section
multi-wire
[mm²]
Cross section
in AWG
0.14-1.5 0.14-1.5 28-16
Fig. 6-61: Connection cross section
HCS03.1E-W0070:
Cross section
single-wire
[mm²]
Cross section
multi-wire
[mm²]
Cross section
in AWG
1,5 1,5 16
Fig. 6-62: Connection cross section X6 (HCS03.1E-W0070)
HCS03.1E-W0100, -W0150 and W0210:
Cross section
single-wire
[mm²]
Cross section
multi-wire
[mm²]
Cross section
in AWG
2,5 2,5 12
Fig. 6-63: Connection cross section X6 (HCS03.1E-W0100…0210)
Note: Make sure the voltage supply for the motor holding brake is
sufficient. In this respect observe the lengths and cross
sections of the cables used.
x6_kabel_anschluss.FH7
X6
holding
brake
PTC /
NTC /
KTY84
(depends on motor type)
shield for
motor cable
AC motor
M
3
A
B
C
D
F
G
U
E
H
3
+24VBr
4
0VBr
1
MotTemp+
2
MotTemp-
A1 A2 A3
X5
Fig. 6-64: Motor cable, temperature monitor and holding brake connection
Connection Cross Section