Operating instructions

6-44 Mounting and Installation Rexroth IndraDrive
DOK-INDRV*-FU*********-IB01-EN-P
HCS03.1E- Type No. of
poles
Type of design
W0070 Connector 4 Screw connection
W0100, W00150 Terminal block 3 Screw connection for
M6 ring cable lugs
W0210 Terminal block 3 Screw connection for
M10 ring cable lugs
Fig. 6-51: Design
Identification of the individual connections:
Identification Significance
A1 phase 1
A2 phase 2
A3 phase 3
(PE) equipment grounding conductor
Fig. 6-52: Identification of the individual connections motor connection
The outputs A1, A2, A3 are short-circuit proof at the device output against
each other and against ground.
HCS02.1E- Cross section
single-wire
[mm²]
Cross section
multi-wire
[mm²]
Cross section
in AWG
W0012, W0028 0,2-4 0,2-4 24-10
W0054, W0070 0,5-10 0,5-10 20-8
Fig. 6-53: Connection cross section
HCS03.1E- Cross section
single-wire
[mm²]
Cross section
multi-wire
[mm²]
Cross section
in AWG
W0070 16 - 6
W0100 35 - 2
W0150 50 2*25 0
W0210 95 2*50 4/0
Fig. 6-54: Connection cross section
HCS02.1E- Tightening torque [Nm]
W0012, W0028 0,5 – 0,6
W0054, W0070 1,2 – 1,5
Fig. 6-55: Tightening Torque
HCS03.1E- Tightening torque [Nm]
W0070 1,5
W0100, W0150 6
W0210 25
Fig. 6-56: Tightening Torque
Short Circuit Protection
Connection Cross Section
Tightening Torque