Operating instructions

6-42 Mounting and Installation Rexroth IndraDrive
DOK-INDRV*-FU*********-IB01-EN-P
X3, Mains Connection
DANGER
High electrical voltage! Danger to life, severe
bodily harm by electric shock!
Always operate the drive controller with plugged on
connector!
HCS02.1E- Type Number of
poles
Type of design
W0012 Screw terminal
block
4 Pins on device
W0028 Screw terminal
block
4 Pins on device
W0054 Screw terminal
block
4 Pins on device
W0070 Screw terminal
block
4 Pins on device
Fig. 6-43: Design
HCS03.1E- Type No. of poles
Type of design
W0070
Connector 4 Screw connection
W0100
Terminal block 3 Screw connection for
M6 ring cable lugs
W0150
Terminal block 3 Screw connection for
M6 ring cable lugs
W0210
Terminal block 3 Screw connection for
M10 ring cable lug
Fig. 6-44: Design
Identification of the individual connections:
Identification Significance
L1 phase 1
L2 phase 2
L3 phase 3
(PE) equipment grounding conductor
Fig. 6-45: Identification of the individual connections mains connection
Note: Only with single-phase operation: connect the connecting lines
of the mains voltage supply L1 and N with the connections L1
and L2.
HCS02.1E- Cross section
single-wire
[mm²]
Cross section
multi-wire
[mm²]
Cross section
in AWG
W0012, W0028 0,2-4 0,2-4 24-10
W0054, W0070 0,5-10 0,5-10 20-8
Fig. 6-46: Connection cross section
Design
Connection Cross Section