Adit 3104 QUICK START GUIDE Part Number: 002-0219-0410 Product Release: 1.
Copyright 2007 Carrier Access Corporation. All rights reserved. The information presented in this manual is subject to change without notice and does not represent a commitment on the part of Carrier Access Corporation. The hardware and software described herein are furnished under a license or nondisclosure agreement. The hardware, software, and manual may be used or copied only in accordance with the terms of this agreement.
QUICK START GUIDE Quick Start In this Guide Unpacking and Inspection Installation Environment User Safety Installation Compliant Installation Ferrite Beads Wall Mounting Rack Mounting (Optional Feature) Adit 3104, 3200 and 3400 Battery Backup Chassis Overview Interface Connectors Reset Button Alarm/Status LEDs Web-Based Management Setting up a CLI Connection Log in Key Enabled Software Features Basic Configuration - Setup Adit for access via Web-Browser Restore Factory Defau
Quick Start Unpacking and Inspection Unpacking and Inspection WARNING! OBSERVE PRECAUTIONS FOR HANDLING ELECTROSTATIC DEVICES. 1. Inspect containers for damage during shipment. Report any damage to the freight carrier for possible insurance claims. 2. Compare packing list with office records. Report any discrepancies to the office. 3. Open shipping containers, be careful not to damage contents. 4. Inspect contents and report any damage. 5.
Quick Start User Safety User Safety CAUTION! WHEN USING YOUR TELEPHONE EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND INJURY TO PERSONS, INCLUDING THE FOLLOWING: z Do not use this product near water for example, near a bathtub, washbowl, kitchen sink or laundry tub, in a wet basement or near a swimming pool. z Avoid using a telephone (other than a cordless type) during an electrical storm.
Quick Start Installation Compliant Installation NOTE: It is important the DS1/E1 Network Interface Cables are secured separately from the power and Signal Cables. 1. Inspect the unit. 2. Mount the unit, see Wall Mounting on page 7, or Rack Mounting (Optional Feature) on page 8 for detailed instructions. 3. Ground the unit. See Grounding the Unit on page 12. WARNING! THE ADIT 3104 IS REQUIRED TO BE PERMANENTLY GROUNDED FOR THE PROTECTION OF USERS AND SERVICE PERSONNEL. DETAILED INSTRUCTIONS.
Quick Start Installation Wall Mounting Before beginning the mounting process, verify that the installation area is a stable environment, clean and free from extremes of temperature, shock, vibration and EMI. See Installation Environment on page 4. Mounting Bracket Back of unit Front of unit Leave adequate space at the front/back for access to connectors The Adit 3000 is delivered with mounting brackets that can easily be attached for quick and easy wall mounting, as shown in the illustration above.
Quick Start Installation Rack Mounting (Optional Feature) NOTE: Rack mounting kits are available for both 19 and 23 inch racks. 1 Rack Unit (RU) of spacing is required above the Adit 3000 in the Rack Mount Unit. To rack mount the Adit 3000, follow the instructions below: 1. Attach bracket ears to Rack Mounting Tray using four #10-32 x 1/4" screws on each side. The Mounting Ears can be used for both a 19 or 23 inch rack. The drawing below shows a top view of the 2 versions.
Quick Start Installation 3. Place the Adit 3000 on the Tray Slide and attach with the 4 screws removed in step 2. screws screws Tray Slide 4. Slide the assembled piece (Adit 3000 and Tray Slide) onto the installed Rack Mounting Tray. 5. Secure the Tray Slide to the Rack Mounting Tray with the attached screws on the Tray Slide. NOTE: the mounting brackets are designed to not allow units to be mounted closer than recommended. Adit 3104 - Release 1.
Quick Start Installation Adit 3104, 3200 and 3400 Battery Backup Note: This is an Optional Feature. The Adit 3104, 3200 and 3400 Battery Backup (P/N 730-0132), is a wall-mount battery backup unit to provide up to 8 hours battery backup. Please see the Battery Backup User Manual for product information and installation instructions, which is provided with unit. 10 Adit 3104 - Release 1.
Quick Start Chassis Overview Chassis Overview Front Alarm Status (4) 10/100Base-T Ethernet (LAN) Reset (1) DS1/E1 (WAN) (E1-future) (1) 10/100Base-T Ethernet (WAN) Tip & Ring Telco Connector Back Ground Adit 3104 - Release 1.
Quick Start Interface Connectors Interface Connectors Front of Adit z (1) DS1 WAN port (RJ-48C). Note: E1 will be in a future release.
Quick Start Interface Connectors Power The Adit 3000 is powered by a limited -48 VDC Power source. The following options are available: AC/DC Converter z Battery Backup module z AC/DC Converter An AC/DC Converter generates 48VDC from any worldwide AC power source. To connect AC power: 1. Plug power connector from AC/DC converter into rear of Adit 3000. 2. Connect AC/DC converter to wall outlet. 3. A green light should appear on the Status LED on the front of the unit.
Quick Start Interface Connectors 25-Pair Telco Connector Tip and Ring Analog Interfaces equipped with standard 25-pair Telco Connectors (female) for connection to key systems, fax machines, modems, and PBXs. Circuit connections are made at the 25-pair telco connectors. A standard 25-pair telephone cable with RJ21X wiring and a male D-type connector at the Adit 3000 end is required.
Quick Start Interface Connectors RS-232 Craft Port (Female DB-9) The RS-232 craft port connector (female) is for connection to an external PC or Hayes-compatible modem for local or remote configuration, management, and performance monitoring using the Adit 3000 Command Line Interface (CLI). The RS-232 craft port connects via a female DB-9 connector on the Adit 3000.
Quick Start Interface Connectors DS1/E1 Connection Ports 1 8 Each DS1/E1 connection port is equipped with a standard RJ-48C (female) on the Adit 3000 unit. Note: E1 will be available in a future release.
Quick Start Reset Button 10/100Base-TX Ethernet The 10/100Base-TX Ethernet (female) ports provide connectivity for Router WAN and/or LAN ports and for management connection via Telnet and/or SNMP to a Network Management System. 1 8 8 Ethernet (RJ-45) 1 The pinouts are as follows: Note: This is a hub pinout, you will need a straight cable to connect to a PC.
Quick Start Alarm/Status LEDs Alarm/Status LEDs LED State Description Critical Off No critical alarms present Red Critical alarms present. Critical alarms include: user-configured manor environmental inputs. Off No major alarms present Red Major alarm present. Major alarms include: user-configured manor environmental inputs, DS1 short, DS1 open, DS1 facility alarm, DS1 RAI, DS1 AIS, DS1 LOF, DS1 LOS, WAN fault, Ethernet fault and dead card alarms.
Quick Start Web-Based Management Web-Based Management The web-based management interface allows you to control various system parameters. The interface is accessed through a web browser. To access the management console: NOTE: The following assumes that you have connected the PC to the LAN port of the Adit 3104. 1. Launch a web browser on your PC in the LAN to which the Adit 3104’s LAN port is connected.
Quick Start Setting up a CLI Connection Setting up a CLI Connection A CLI connection will require the LAN or WAN IP address of the unit. Note: If the WAN IP address is used, the remote admin WAN access must be enabled with the following command sequence: Command Username: admin Description Log into the system (username and password). Password: ******** Adit 3104> enable Enter the Privileged mode. Password: ******** Enter password for the Privileged mode.
Quick Start Log in Log in After successful connection, via telnet or HyperTerm, the user must login. Default Logins are: Login: admin Password: admin123 After successful login the prompt will be displayed as follows: Adit 3104> NOTE: It is recommended that you change your password from the default. Adit 3104 - Release 1.
Quick Start Key Enabled Software Features Key Enabled Software Features The Adit 3104 has additional features that are not provided on the base system. These features can be purchased with the product or added later as needed. These features are enabled via a Software Key (example: G.729). The number of keyed features may expand with the development of the product, therefore to see a list of current keyed features, or to purchase a key, contact Carrier Access Customer Service or Sales.
Quick Start Basic Configuration Basic Configuration The following configuration is divided into logical sections, where each section configures an additional function. The first must be configured before the second and so forth, however, you may stop at any section and not add the following feature. NOTE: The order in which commands are entered can affect the successful provisioning of the Adit 3104.
Quick Start Basic Configuration Restore Factory Defaults If the unit is not out-of-the-box, you may want to verify that the unit is set to defaults. Note: this will reset the IP address back to the default setting of 192.168.1.1. In the web-browser: 24 z Select Advanced from the Navigation bar z Select Restore Defaults z Select OK to restore defaults Adit 3104 - Release 1.
Quick Start Basic Configuration Modify Default Admin User For security purposes it is recommended that the Administrator User be changed from the default settings. Modify the Administrator User in the web-browser: z Select Advanced from the Navigation bar z Select Users icon z Select Administrator, to open the profile. Adit 3104 - Release 1.
Quick Start Basic Configuration z 26 Modify the User information, and select OK to save. It is important to note that you need to have a minimum of one user with Administrative Privileges. For users with other access levels, add a New User. Note: For security purposes, the password should be changed. Adit 3104 - Release 1.
Quick Start Basic Configuration Configure Ethernet WAN Interface In the web-browser: 1. Select Network Connections from the Navigation bar. 2. It is recommended that you disable/delete the Serial1 port. 3. Select (click) Ethernet 2 (WAN Ethernet) connection to configure. 4. Select the Enable button, to configure the WAN Ethernet up (or in-service). 5. Select the Settings button. Adit 3104 - Release 1.
Quick Start Basic Configuration 6. Set Internet Protocol to Obtain an IP Address Automatically, from the pulldown menu. This will enable the Adit 3104 as a DHCP Client. Leave the other fields to their default settings. 7. Select Apply to apply the new settings. 28 Adit 3104 - Release 1.
Quick Start Basic Configuration Configure Serial1 as WAN In the web-browser: 1. Select Network Connections from the Navigation bar. 2. Select Serial1. 3. Select Settings button. 4. Set Network to WAN. 5. Select Apply to apply the new settings. Adit 3104 - Release 1.
Quick Start Basic Configuration 6. Select the Enable button. 30 Adit 3104 - Release 1.
Quick Start Basic Configuration Configure the Adit 3104 as a SIP Line Gateway In the web-browser: 1. Select Voice Over IP from the Navigation bar. 2. Select Use SIP Proxy. 3. Enter Softswitch IP Address, User name and Password. 4. Select applicable Codecs. 5. Select Apply to apply the new settings. Adit 3104 - Release 1.
Quick Start Basic Configuration 6. Select the Phone Settings tab. 7. Select the Action icon on line #1 to edit. 32 Adit 3104 - Release 1.
Quick Start Basic Configuration 8. Enter a telephone number in the User ID field and select OK. 9. Repeat this step for each line you would like to have register with your Softswitch. Adit 3104 - Release 1.
Quick Start Basic Configuration 34 Adit 3104 - Release 1.