System information

Adit 3000 CLI - Release 1.6 4-27
Global Configuration Mode
log
log security notify
Use the log security notify command to set the remote security notify level.
Syntax: (config)# log security notify {error|info|ip-address address
|none|warn}
Example: (config)# log security notify warn
Supported Platforms:
Adit 3104, Adit 3200, Adit 3500
log sip
Use the log sip command to configure SIP logging. To stop a SIP log, see no log sip command on
page 4-41.
Syntax: (config)# log sip {buffer-fill {0|1}|buffer-size kilobytes
|display number|enable|level {detail|non-detailed}}
Example: (config)# log sip buffer-fill 0
Supported Platforms:
Adit 3104, Adit 3500
Field Definition
error Notify for error level.
info Notify for information level.
ip-address address Enter IP address of remote system to notify.
none No notification.
warn Notify for warning level.
Field Definition
buffer-fill {0|1} Define the method of loading the buffer.
0 = Circular Buffer - the buffer will store a continuous stream of data
by starting again at the beginning of the buffer after reaching the end.
Default.
1 = Fill Until Full - the buffer will fill until it is full. The user will
have to clear the log manually.
buffer-size kilobytes Configure the SIP log size. Range is 1 - 250 KB, with a default of 100
KB.
display number Defines the number of lines per message. 0 = full
enable Enable SIP logging.
level Defines the logging level.
detailed - Set logging level to detail.
non-detailed - Set logging level to non-detail