Adit 3000 Series and Multi-Service Router (MSR) Card CLI Referece Manual

Adit 3000 (Rel. 1.6) and MSR Card (Rel 2.0) CLI 6-9
Configuration - T1 Controller Mode
loopdetect
Use the Controller T1 loopdetect command to enable the detection of CSU or NIU loop code.
Syntax: (config-cont-t1-{n})# loopdetect {csu|niu|none}
Example: (config-cont-t1-1)# loopdetect csu
Supported Platforms:
Adit 3104, Adit 3200, Adit 3500
no commands
no ds0-group
Use the Controller T1 no ds0-group command to ungroup DS0 timeslots. To group DS0s, see
ds0-group command on page 6-4.
Syntax: (config-cont-t1-{n})# no ds0-group
Example: (config-cont-t1-1)# no ds0-group
Supported Platforms:
Adit 3104, Adit 3200, Adit 3500
no pri-group
Use the Controller T1 no pri-group command to ungroup PRI timeslots. To group PRI timeslots,
see pri-group command on page 6-10.
Syntax: (config-cont-t1-{n})# no pri-group timeslots range
Example: (config-cont-t1-1)# no pri-group timeslots 1-4
Supported Platforms:
Adit 3104, Adit 3500
Field Definition
csu Enable detection of CSU loop codes (10000 for loop up, 100 for loop
down)
niu Enable detection of NIU loop codes
none Disable detection. Default.
Field Definition
range PRI timeslot range, in the format n-n (1-4). Range is 1 - 23.