Instruction manual

9
O p e r a t i o n a n d I n s tr u c t i o n M a n u a l
Granita Machine Page
For machines with a handle locking system,
remove the tap padlock and then take the locking
tap rod away (#8 arrow I), remove the fastener
(#7 arrow J), disconnect the dispensing handle
(#1 arrow K). By pushing upward (arrow L), take
the spring (#3) out from its holder (#2 arrow M),
then push the piston downward (#6 arrow N),
remove the o-ring (#5 arrow P) and the special
gasket (#4 – arrow Q).
Proceed to clean everything with water and neutral
soap, rinse and reassemble without damaging the
gaskets as follows: put in place the special gasket
(#4 – arrow A), put the o-ring (#5) back in its piston
slot (#6 arrow C), insert the spring (#3 arrow
D), put the cap in place (#2 arrow E), put the
handle in place (#1 arrow F), insert the fastener
(#7 arrow G), and if you want to lock the tap,
insert the locking tap rod (#8 – arrow H) and lock.
CLEANING THE FAUCET
Figure 8