Instruction manual

O p e r a t i o n a n d I n s tr u c t i o n M a n u a l
Granita Machine Page
26
Trouble Possible Causes Remedy
Machine overheats Machine vents are blocked Check that nothing is obstructing the
vents
The tap drips O-rings may be improperly
placed
Make sure that the o-rings are in place
and have no cuts.
Check that the piston is correctly closed
and nothing is obstruction its outlet.
Verify that the spring works correctly.
Machine is not cooling the
product*
Voltage may be labelled
improperly
Does the machine have
power?
The condenser is dirty
No refrigerant
Verify that the voltage supply matches
the label on the back of the machine.
Check to see if the machine is plugged
in.
Clean the condenser carefully with a
brush trying not to damage the ribs.
See figure 7.
Contact authorized service agency.
The unit does not work No power
Switch Power cord loose or
damaged
Defective
Wiring disconnected
Connect unit to power supply.
Locate problem and correct. Replace
power cord if necessary.
Replace switch.
Check wiring for loose connection or
broken wire.
One of the augers does not
work
Motor connection loose
Defective switch
Auger is stuck
Bad gear reducer motor
Check wiring to motor.
Replace switch.
Check auger, replace if necessary.
Replace.
No pilot light when unit is on Defective wiring connection
Defective density switch
Burned out bulb
Defective thermostat
Check wiring.
Check switch.
Replace bulb.
Replace thermostat.
Compressor does not start Defective overload
Defective relay
Defective compressor
Replace.
Replace.
Replace.
TROUBLE SHOOTING GUIDE