Technical information
Rev. 12/2002
CARPIGIANI Operation Manual - LB 302, LB 502, LB 1002, LB 302 G, LB 502 G, LB 1002 G
Page 11
Figure 8
PART 3
INITIAL CLEANING PROCEDURE
This is a new machine and it must be completely disas-
sembled, washed and sanitized before starting. Proceed
as follows:
PRELIMINARY CLEAN-OUT
• With the machine off and the beater front door closed,
use the hose and shutoff valve on the front of the ma-
chine to put water into the barrel.
• With machine on, press the "Clean Out" button and
allow the beater to run for the proper length of time.
• The machine will run for about 3 minutes and then will
automatically stop. The timer helps prevent unneces-
sary wear on the sliding shoes and barrel.
• Drain all water from barrel and open the door.
BEATER DISASSEMBLY
(MODELS LB 302 - LB 502 - LB 1002)
• Remove the beater.
Perform this operation with extreme care.
The beater may be damaged if it falls to the ground
or is impacted against another object.
• Remove the rear plug seal then remove the beater lip
seal from its seat on the beater shaft (ref Fig. 10).
Figure 9
Figure 10
Beater mounted on models: LB 302 - LB 502
Beater mounted on models: LB 1002
Beater mounted on models: LB 1002
Beater mounted on models: LB 302 - LB 502
Plug
seal
Beater seal
Plug seal
Stuffing
box