Technical information

Rev. 12/2002
CARPIGIANI Operation Manual - LB 302, LB 502, LB 1002, LB 302 G, LB 502 G, LB 1002 G
Page 11
Figure 8
PART 3
INITIAL CLEANING PROCEDURE
This is a new machine and it must be completely disas-
sembled, washed and sanitized before starting. Proceed
as follows:
PRELIMINARY CLEAN-OUT
With the machine off and the beater front door closed,
use the hose and shutoff valve on the front of the ma-
chine to put water into the barrel.
With machine on, press the "Clean Out" button and
allow the beater to run for the proper length of time.
The machine will run for about 3 minutes and then will
automatically stop. The timer helps prevent unneces-
sary wear on the sliding shoes and barrel.
Drain all water from barrel and open the door.
BEATER DISASSEMBLY
(MODELS LB 302 - LB 502 - LB 1002)
Remove the beater.
Perform this operation with extreme care.
The beater may be damaged if it falls to the ground
or is impacted against another object.
Remove the rear plug seal then remove the beater lip
seal from its seat on the beater shaft (ref Fig. 10).
Figure 9
Figure 10
Beater mounted on models: LB 302 - LB 502
Beater mounted on models: LB 1002
Beater mounted on models: LB 1002
Beater mounted on models: LB 302 - LB 502
Plug
seal
Beater seal
Plug seal
Stuffing
box