User's Manual
Trailblazer Installation and User Manual version 1.03 44
6.4.2 Setting the V35 enable and port location
To enable the V35 data port,
open up the Hyperterminal™
interface and if you are
communicating with a CPE unit
after booting type: [stop]. If you
are
connected to a base unit it will
stop on it’s own after a minute.
Then type in:
[wee 5 1] or [wee 5 2]
depending on which line no you
wish to be used as a data path for
the Ethernet connection. The
system should respond back
with: 0005: 02 as shown above.
To disable theV35 data port, open up the HyperTerminal™ interface and type in:
[wee 5 FF] . The system should respond back with: 0005: FF .
6.4.3 Received Signal Strength Indicator (RSSI)
The RSSI value can be accessed
through the Command Line
Interface using the following
command:
rdm ff28 4 <enter>.
The figure at right shows the
output for the RSSI from the CPE
unit. The RSSI value is repeated 4
times, but just look at a single
number. The figure to the right
shows an RSSI of 0C. The RSSI
should be 8 or higher. If the
value displayed contains an alphabetic character (A, B, C, D, E or F), the value is greater
than 9. The undesirable RSSI values are from 00 to 07.
The RSSI command can be used on the base unit. The above figure displays the results
of the command. 3 of the 4 values will always read 00, just ignore these values. 1 of the
4 numbers should be greater than 7. If the value displayed contains an alphabetic