User's Manual

Trailblazer Installation and User Manual version 1.03
7
is recommended for any cable runs over 100 feet. The chart below provides the loss
factor for several popular cable sizes.
Coax Cable Attenuation (dB per 100 feet)
Cable Type
at 2.5 GHz
at 5.8 GHz
LMR 400
6.8 dB
10.8 dB
LMR 500
5.5 dB
8.9 dB
LMR 600
4.4 dB
7.3 dB
1/2 inch LDF Heliax
3.9 dB
7.0 dB
LMR 900
3.0 dB
4.9 dB
7/8 inch LDF Heliax
2.3 dB
3.7 dB
Table 3: Coax Cable Loss Table
2.1.7 Data Cable Recommendations
The new design of the Trailblazer replaces proprietary cables with standard CAT5
Ethernet cables terminated with RJ45 connectors for the sync and repeater functions.
NOTE: Feed the cable through the weatherproof cord grip before terminating it. The
cord grip is too small to accept an RJ45 connector especially while occupied by other
cables!
2.1.8 General Tools
ESD Gear
Desktop PC or Laptop Computer with Windows
Wrench Set
Socket Set
Screwdriver Set
Multi Meter
Butt-set or Test Telephone with bare wire connection
Wire Cutters
Wire Strippers
Vapor Wrap
Electrical Tape
Small Non-Conductive adjustment tool
Safety Gear