User's Manual
Trailblazer Installation and User Manual version 1.02 12
Cable Size
(A.W.G.)
(mm)
Ohms/100ft
(both legs )
feet per Ohm
(both legs)
if feeding 13.8,
distance with 5%
(voltage loss 2pr.)
if feeding 24,
distance with 5%
(voltage loss 2pr.)
14 1.63 0.516 194 1783 6202
16 1.29 0.818 122 1125 3912
18 1.09 1.302 77 707 2458
19 0.91 1.642 61 560 1949
22 0.64 3.3 30 279 970
24 0.51 5.24 19 176 611
26 0.41 8.32 12 111 385
Table 4: Feed Cable Sizing and Distance for the Traiblazer
2.3.3 Connecting the POTS Lines
Connect POTS lines as shown in the figure below using the black screw
terminals on the units’ interface cards. Remember to connect the telephone
line(s) from the phone company to the Base unit and the handset(s) to the CPE
unit. The location of your active lines will depend on the time slots selection
made by the CPE and the bandwidth used. Note the “Active Line” label on your
Base and CPE units.
CPE
#0
Line
2
Line 1
CPE
#1
Line
2
Line 1
CPE
#2
Line
2
Line 1
CPE
#3
Line
2
Line 1
Repeater
Ports
Re
p
eater “A”
Re
p
eater “B”
Sync
Port
RJ45
Screw
Terminals
10BaseT
Port
Ethernet