User's Manual

Trailblazer Installation and User Manual version 1.02 45
6.4.2 Setting the V35 enable and port location
To enable the V35 data port,
open up the Hyperterminal™
interface and if you are
communicating with a CPE unit
after booting type: [stop]. If you
are connected to a base unit it
will stop on it’s own after a
minute.
Then type in:
[wee 5 1] or [wee 5 2]
depending on which line no you
wish to be used as a data path
for the Ethernet connection. The
system should respond back with: 0005: 02 as shown above.
To disable theV35 data port, open up the HyperTerminal™ interface and type in:
[wee 5 FF] . The system should respond back with: 0005: FF .
6.4.3 Received Signal Strength Indicator (RSSI)
The RSSI value can be accessed
through the Command Line
Interface using the following
command:
rdm ff28 4 <enter>.
The figure at right shows the
output for the RSSI from the CPE
unit. The RSSI value is repeated
4 times, but just look at a single
number. The figure to the right
shows an RSSI of 0C. The RSSI
should be 8 or higher. If the
value displayed contains an alphabetic character (A, B, C, D, E or F), the value is
greater than 9. The undesirable RSSI values are from 00 to 07.