User's Manual
Trailblazer Installation and User Manual version 1.02 8
LMR400 will work fine. Heliax™ is recommended for any cable runs over 100
feet. The chart below provides the loss factor for several popular cable sizes.
Coax Cable Attenuation (dB per 100 feet)
Cable Type at 2.5 GHz at 5.8 GHz
LMR 400 6.8 dB 10.8 dB
LMR 500 5.5 dB 8.9 dB
LMR 600 4.4 dB 7.3 dB
1/2 inch LDF Heliax™ 3.9 dB 7.0 dB
LMR 900 3.0 dB 4.9 dB
7/8 inch LDF Heliax™ 2.3 dB 3.7 dB
Table 3: Coax Cable Loss Table
2.1.8 Data Cable Recommendations
The new design of the Trailblazer replaces proprietary cables with standard
CAT5 Ethernet cables terminated with RJ45 connectors for the sync and
repeater functions.
NOTE: Feed the cable through the weatherproof cord grip before terminating it.
The cord grip is too small to accept an RJ45 connector especially while occupied
by other cables!
2.1.9 General Tools
• ESD Gear
• Desktop PC or Laptop Computer with Windows™
• Wrench Set
• Socket Set
• Screwdriver Set
• Multi Meter
• Butt-set or Test Telephone with bare wire connection
• Wire Cutters
• Wire Strippers
• Vapor Wrap
• Electrical Tape
• Small Non-Conductive adjustment tool
• Safety Gear