User's Manual

FT-512 Trailblazer Installation and User Manual version 1.08 40
6.4 Technical Specifications 8 Line FXS plug in card
FEATURES:
Worldwide dial-up telephone network compatibility
Transient protection to 5 kilovolts
Superior voice solution with low noise and excellent line impedance matching
Designed for maximum performance with modems up to V.92
All CLASS services fully supported including Caller ID and CWID
Pay phone loop reversal detect and optional 12/16 kHz Signal Pulse Metering (TTX)
detection
Complies with the requirements of TIA/EIA/IS-968 (FCC), UL 1950, UL 60950, EN 60950,
IEC60950, EN55022B, CISPR22B, EN55024, and TRB-21
GENERAL SPECIFICATIONS
Product Description Foreign Exchange Office Card
DS-0 lines 2, 4 or 8 depending on order
Regulatory
TIA/EIA/IS-968 (FCC), UL 1950, UL 60950, EN 60950, IEC60950, EN55022B,
CISPR22B, EN55024, and TRB-21
Line and Balance Impedance Both resistive and reactive can be set per country requirements
2 WIRE LINE SPECIFICATIONS
Maximum Loop Length 1500 ohms or 18 ma.
Ring Equivalent Number 0.3B per line
Ring Detect Threshold 24-110 Vrms, 17-34 Hz
Ring Balanced sinusoidal
Idle channel noise – 2w port u-Law, -16 dBrnC, A-Law, -74 dBmp
Idle channel noise – PCM side u-Law, -18 dBrnC, A-Law, -69 dBmp
Longitudinal Balance L-T -53dB, T-L - 46dB, 4-L -46dB
Gain Tracking Ref 1014 Hz, -10dBm0, +/- 0.25 dB from -40 to 0dBm0
Nominal Transmit Level 0.0 dBm0, factory programmable
Nominal Receive Level -2.0 dBm0, factory programmable
2 wire port return loss 26 dB min.
POWER REQUIREMENTS &
CONSUMPTION
Power provided by FT-512 card
Operating Current: no load, full load Less than 100 mw with all lines active
ENVIRONMENTAL & PHYSICAL
SPECIFICATIONS
Operating Temp -30 to +60 Degrees C (Ambient with Solar Shielding)
Humidity 0 to 95% - Non-Condensing
Shock and Vibration Mil Standard 810 D
Shipping Weight 4 lbs; 2 kg
WARRANTY
1 Year Parts and Labor
Specifications Subject to Change without Notice.