User's Manual
29
4.3 Troubleshooting
4.3.1 Units are on the Bench
The following flowchart should help focus in on the fault.
Assuming you have a pair of boards on the bench with adequate power
connected.
Figure 20: LED - D1
Is the Microprocessor heartbeat LED -D1, flashing?
D4 should be on steady- otherwise the unit is resetting
D5 should not be lit – other wise it getting packet errors
D6 should be flashing rapidly – showing the micro processor is awake.
If you connect the GUI with a console cable, are you able to communicate.
Once communication is established:
Do the SFD numbers match?
Are both Administrative channels the same?
Is there an Operating channel set in the “Master”?
Is one unit a “Slave” and the other a “Master”?
Are both rotary switches set on 0?
Are the CDMA codes the same on each pair? (1 through 4)
Are both Data Rates set the same?
Heartbeat LED - D1