Specifications

45
Types
Split Core Current Transformers
CTD-6S CTD-8S
Types
CTD-9S CTD-10S ROG400
CTD-5S
Class
Bus-bar size
Dimensions (H x W x D)
Standards
Accuracy class
depending on
the burden output
Primary current
1
27x32 mm
93.9x83x60 mm
EN60044-1
Burden (VA)
Class
1 3
100A 1.5
125A 1.5 1.5
150A 1.5 2.5
200A 1.5 5
250A 1.5 5
300A 2.5 7.5
400A 5 10
1
52x51mm
113.9x107x60 mm
EN60044-1
Burden (VA)
Class
1 3
150A 1.5
200A 1.5 2
250A 1.5 3.75
300A 1.5 5
400A 2.5 5
500A 5 10
600A 7.5 15
700A 7.5 15
750A 7.5 15
800A 10 15
1000A 10 15
1
81x31 mm
132.9x87x60 mm
EN60044-1
Burden (VA)
Class
1 3
150A 1.5
200A 1.5
250A 2
300A 2
400A 3 5
500A 5 7
600A 6 10
700A 6 10
750A 8 12
800A 8 12
1000A 10 15
1200A 12 15
1250A 12 15
1500A 15 20
1600A 15 20
2000A 20 25
2500A 25 30
Class
Bus-bar size
Dimensions (H x W x D)
Standards
Accuracy class
depending on
the burden output
Primary current
1
126x36 mm
177.9x91.7x60 mm
EN60044-1
Burden (VA)
Class
1 3
400A 3
500A 2 4
600A 4 6
700A 4 8
750A 4 8
800A 4 8
1000A 6 10
1200A 8 12
1250A 8 12
1500A 10 15
1600A 10 15
2000A 15 20
2500A 20 25
3000A 25 30
3200A 25 30
4000A 25 30
1
126x51 mm
177.9x106.7x60 mm
EN60044-1
Burden (VA)
Class
1 3
400A 1 7
500A 3 10
600A 5 12
700A 8 15
750A 10 15
800A 10 15
1000A 12 20
1200A 15 25
1250A 15 25
1500A 20 30
1600A 20 30
2000A 25 40
2500A 30 50
3000A 30 50
3200A 30 50
4000A 30 50
1% FS
40mm max
54x29x17mm
Power supply: 10 to 30 VDC.
Primary current: 0 to 400 ADC.
Output: 4 to 20 mADC
NOTE: operating frequen-
cy: 48 to 62 Hz; max
system voltage: 0.72 kV;
rated insulation level:
3kV/1min @ 50Hz; secu-
rity factor: 5; rated
secondary current: 5A
standard (1A on
request); DIN–rail or
panel mounting. All the
products are CE marked.
NOTE: operating frequen-
cy: 48 to 62 Hz; max
system voltage: 0.72 kV;
rated insulation level:
3kV/1min @ 50Hz; secu-
rity factor: 5; rated
secondary current: 5A
standard (1A on
request); DIN–rail or
panel mounting. All the
products are CE marked.
ROG400Split core CTD
series