User guide

24-16
Pressure Switches, component tested
http://products.ecc.emea.honeywell.com/europe
16
17
18
19
20
21
22
23
24
25
26
27
28
16
Maximum pressure monitor with selfmonitoring sensor
for steam and hot water
Maximum pressure monitor of 'special construction' (DA)
Kind of pressure overpressure, relative
Pressure connection internal thread G1/4, external thread G1/2
Electrical connection Plug DIN 43650
Protection class IP54
Housing material rugged housing of seawater resistant aluminium die casting GD Al Si
12
Sensing element material 1.4104 + 1.4571
Media temp. -20 ... 70
o
C
Media temp. limit temperatures up to 85
o
C are allowable for short periods. Higher
temperatures are possible, provided that the limit is safeguarded by
suitable measures (e.g. water tube trap, see Accessories for Pressure
Switches / Transmitters)
Ambient temperature -20 ... 70
o
C
Ambient temp. limit at temperatures below 0
o
C, ensure that no water condensation can
arise in the sensor and in the switching device
Switch function/capacity SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions add the type numbers below to the listed type numbers for extra
functionality as described
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100
mA, min. 5 Vdc, 2 mA. And others not available with adjustable
switching difference.
-301: terminal connection housing, IP65
-513: Gold-plated contacts, single-pole switch-over. Switching
differential permanent. IP65. Switching capacity: max. 24 Vdc, 100
mA, min. 5 Vdc, 2 mA, suitable isolating switching amplifier,
degree of protection EEx-i
-576: (only DWAM) Normally closed contact with resistance
combination for maximum pressure monitoring. Gold-plated
contacts. Housing with surface protection (chemical version), IP65
-577: (only DWAM) Normally closed contact with reclosing lock-
out and resistance combination for maximum pressure monitoring.
Housing with surface protection (chemical version), IP65
Certificates • TUEV-DW-04-132 for DWAM ...according VdTUEV Memorandum
Pressure 100/1, Issue 4.83
• TUEV-DW-04-133 for DWAMV ...according VdTUEV
Memorandum Pressure 100/1, Issue 4.83
• CE-0035BN0005 according Directive 97/23/EC (Module B + D) for
DWAM
• CE-0035BN0006 according Directive 97/23/EC (Module B + D) for
DWAMV
• SIL3 according IEC 61508