User guide

21-15
Thermostatic Mixing Valves
16
17
18
19
20
21
22
24
23
25
26
27
28
TM200 thermostatic mixing valves provide control of the water temperature and are used: - For
centralised control on hot water supply units or for localised control adjacent to point-use outlets. Or
for use with solar-heated hot water units with dual energy source. - In heating systems with underfloor
heating or for limiting boiler return temperatures. Where a system includes a hot water circulation
circuit, a KB191 return flow retarder unit (see accessories) must be fitted to prevent cold water
backfeeding and cooling the mixed water at the outlets.
With threaded male connections 3/4 inch
With 22 mm soldered connections
Accessories
Spare Parts
Thermostatic mixing valve with scald protection, TM200
Media Water
Body material brass
Max. media temperature 90
o
C
Temp. setpoint range 30 ... 60
o
C
Additional description • Highly sensitive thermal element with good all-round water
temperature sensing, even at low flow rates
• Simple setting of the required water temperature
• Scald protection - the hot water inlet is automatically cut off if the
cold supply fails provided that the hot water inlet temperature is at
least 10 K higher than that of mixed water setting
• The cold water inlet is automatically cut off if the hot supply fails
• Inner components are of scale-resistant materials
Port connection type
Type
external threads
TM200-3/4A
Port connection type
Type
soldering
TM200-3/4B
Return flow-retarder unit for fitting to systems which include a hot water circulation
circuit - to prevent cold water backfeeding and cooling the mixed water at the outlets
KB191-3/4
Control piston with integral sensing element
TM200A-30/60