User guide
12-4 
Wireless
http://products.ecc.emea.honeywell.com/europe
2
3
4
5
6
7
8
9
10
11
12
13
14
Wireless universal mixing valve controller for heating or cooling zone control. The controller receives 
heat demand signals (RF 868,3 MHz)from thermostats CM67RFMV or CM67z, or from the Hometronic 
operating unit HCM200D-xx.
The CM67RFMV also provides parameter settings for: minimum water temperature setpoint, mixing 
valve runtime, pump after running ime and heating or cooling operation mode.
Controller
Packages
Additional products for HM80
Universal mixing valve controller 
Control output signal • 2x 230 V (3 A) on relay contacts for mixing valve open/close (not 
potential free contacts!)
• 230 V (3 A) on relay contact for pump on/off (not a potential free 
contact!)
Control functions room temperature control; water temperature control (optional)
Manual operation functions push buttons for valve open/close
LED functions mixing valve open/close: red/green; pump on: green; and several 
error messages: red
Power supply 230 V;50Hz; max. 1380 VA
RF communication distance 30 m
Blocking immunity Receiver class 2 (ETSI EN300220-1 version 1.3.1) 
Protection class IP54
Mounting DIN-rail or wall
Housing (HxWxD) 161,5 mm; 121 mm; 46 mm
Product description
Type
Universal mixing valve controller
HM80
Product description
Type
1x CM67RFMV, 1x HM80, 4x Eurofix cable glands
HMC80
1x CM67RFMV, 1x HM80, 4x Eurofix cable glands, 1x T7414C1012
HMC82
Chronotherm room thermostat
CM67RFMV
Flow temperature sensor (optional)
T7414C1012