Datasheet
10 Specifications are subject to change without notice (30.06.2011)
RGC...E
EMC Immunity IEC/EN 61000-6-2
Electrostatic Discharge (ESD)
Immunity IEC/EN 61000-4-2
Air discharge, 8kV Performance Criteria 1
Contact, 4kV Performance Criteria 1
Electrical Fast Transient
(Burst) Immunity IEC/EN 61000-4-4
Output: 2kV, 5kHz Performance Criteria 1
Input: 1kV, 5kHz Performance Criteria 1
Electrical Surge Immunity IEC/EN 61000-4-5
(for RGC...E)
Output, line to line, 1kV Performance Criteria 1
Output, line to earth, 2kV Performance Criteria 1
Input, line to line, 1kV Performance Criteria 2
Input, line to earth, 2kV Performance Criteria 2
Electrical Surge Immunity IEC/EN 61000-4-5
(for RGC...EP)
Output, line to line, 1kV Performance Criteria 1
Output, line to earth, 2kV Performance Criteria 1
DC lines, line to line, 500V Performance Criteria 2
DC lines, line to earth, 500V Performance Criteria 2
Signal lines, line to earth, 1kV Performance Criteria 2
Radiated Radio Frequency
Immunity IEC/EN 61000-4-3
10V/m, 80 - 1000 MHz Performance Criteria 1
10V/m, 1.4 - 2 GHz Performance Criteria 1
3V/m, 2 - 2.7 GHz Performance Criteria 1
Conducted Radio Frequency IEC/EN 61000-4-6
Immunity
10V/m, 0.15 - 80 MHz Performance Criteria 1
Voltage Dips Immunity IEC/EN 61000-4-11
0% for 10ms/20ms, Performance Criteria 2
40% for 200ms Performance Criteria 2
70% for 500ms Performance Criteria 2
Voltage Interruptions Immunity IEC/EN 61000-4-11
0% for 5000ms Performance Criteria 2
EMC Emission IEC/EN 61000-6-4
Radio Interference
Voltage Emission (Conducted) IEC/EN 55011
0.15 - 30MHz Class A (industrial) with filters
- see filter information
IEC/EN 60947-4-2, 60947-4-3
Class A (no filtering needed)
Radio Interference
Field Emission (Radiated) IEC/EN 55011
30 - 1000MHz Class A (industrial)
Electromagnetic Compatibility
Conformance IEC/EN 62314
IEC/EN 60947-4-2
IEC/EN 60947-4-3
Agency Approvals UL508 Listed (E172877)
cUL Listed (E172877)
VDE 0660-109
GL
12
Short Circuit Current Rating 100kA, UL508
Agency Approvals and Conformances
Operating Temperature
11
-40°C to 80°C (-40˚F to +176˚F)
Storage Temperature -40°C to 100°C (-40˚F to +212˚F)
RoHS (2002/95/EC) Compliant
Impact resistance
(EN50155, EN61373) 15/11 g/ms
Vibration resistance
(2-100Hz, IEC60068-2-26,
EN50155, EN61373) 2g per axis
Relative humidity 95% non-condensing @ 40˚C
UL flammability rating
(housing) UL 94 V0
Environmental Specifications
11. Operating temperature range for RGC..P (overtemperature protection) is -30˚C to 70˚C (-22˚F to 158˚F)
12. Applicable to models RGC1...15.KE, RGC1...20.KE and RGC1...30.KE