Datasheet
7
Carlo Gavazzi Automation S.p.A.
ICS08 IO-Link 3-wire DC
ICS08 IO-Link 3-wire DC DS EN11/05/2018
Response times
Operating frequency (f) ≤ 2 KHz
Indication
Standard IO mode:
Yellow LED Output Description
OFF OFF
N.O. output, target not present
N.C. output, target present
ON ON
N.O. output, target present
N.C. output, target not present
Blinking
f: 2Hz Short-circuit or overload
f: 1Hz Temperature alarm (if enabled)
IO-Link mode:
• LED is ON for 0.75 s and OFF for 0.075 s
• Possibility to disable the LED
Environmental
Ambient temperature
Operating: -25° to +80°C (-13° to +176°F)
Storage: -30° to +80°C (-22° to +176°F)
Ambient humidity
Operating: 35% to 95%
Storage: 35% to 95%
Vibration
10 to 55 Hz, amplitude 1.0 mm; sweep cycle 5
min; in X, Y and Z direction
IEC 60068-2-6
Shock 30 G /11 ms. 10 shocks in X, Y and Z direction IEC 60068-2-27
Degree of protection IP67 IEC 60529; EN 60947-1
Compatibility and conformity
EMC protection
IEC 61000-4-2 Electrostatic discharge
8 kV air discharge
4 kV contact discharge
IEC 61000-4-3 Radiated radiofre-
quency
3 V/m
IEC 61000-4-4 Burst immunity 2 kV
IEC 61000-4-6 Conducted radio fre-
quency
3 V
IEC 61000-4-8 Power frequency mag-
netic elds
30 A/m
MTTF
d
4513 years @ 50°C (122°F)
Approvals
®
CCC is not required for products rated ≤ 36 V