Datasheet
2
Carlo Gavazzi Automation S.p.A.
IBS04, ICS05 IO-Link 3-wire DC
IBS04, ICS05 IO-Link 3-wire DC DS EN10/07/2018
IO-Link sensors
•  The devices can be operated in IO-Link mode once connected to an IO-Link master, or in standard I/O mode.
•  In IO-Link mode the switching signals of the sensor are made available in the process data via the IO-Link interface.
•  Several sensor functions can be set via the IO-Link interface:
 ► Adjustable switching distance: 62% or 100% of the maximum switching distance.
 ► Adjustable hysteresis: standard or increased value.
 ► Divider function: the sensor  gives a signal after  a specied number of actuation pulses has been 
reached.
 ► Switch-on delay: the switching pulse is generated after the sensor actuation.
 ► Switch-o delay: the generation of the switch signal is delayed by the set time after sensor actuation.
 ► Temperature error: temperature is out of specications.
 ► Temperature over-run and under-run: temperature is out of the limits dened by the user.
References
Order code
I   S     F     
Enter the code option instead of 
Code Option Description
I - Inductive sensor
B Cylindrical housing with smooth barrel
C Cylindrical housing with threaded barrel
S - Stainless steel housing
04 Ø4 housing
05 M5 housing
S Short housing with smooth barrel
S23 Short housing with thread length of 23 mm
F - Flush
08 Sensing distance 0.8mm
15 Sensing distance 1.3mm
M5 M8 plug
A2 2 m PVC cable
NO NPN – normally open output
NC NPN – normally closed output
PO PNP – normally open output
PC PNP – normally closed output
IO IO-Link programmable version
Additional characters can be used for customized versions.