Datasheet
5
Carlo Gavazzi Automation S.p.A.
IBS04, ICS05 IO-Link 3-wire DC
IBS04, ICS05 IO-Link 3-wire DC DS EN10/07/2018
Sensing
Detection
Rated operating distance S
n
0.8 mm standard range or 1.3 mm extended range
Reference target
The operating distance is measured according to IEC 60947-5-2, using a
standard target moving axially.
This target is square shape 1 mm thickness, made of steel e.g. type Fe 360
as dened in ISO 630 and it shall be of the rolled nish.
The length of the side of the square is equal to
– the diameter of the circle inscribed on the active surface of the sensing face,
or
– three times the rated operating distance S
n
whichever is greater
Assured operating sensing distance
(S
a
)
0 ≤ S
a
≤ 0.81 x S
n
(e.g. with S
n
of 1.3 mm, S
a
is 0 ... 1.053 mm)
Eective operating distance (S
r
) 0.9 x S
n
≤ S
r
≤ 1.1 x S
n
Usable operating distance (S
u
) 0.9 x S
r
≤ S
u
≤ 1.1 x S
r
Temperature drift ≤ +/-10%
Hysteresis (H) 1...20%
Y
X
S
T
S: sensor
T: target
-3,9 03,9 7,811,715,619,523,427,331,235,1
-98,4
-73,8
-49,2
-24,6
0
24,6
49,2
73,8
98,4
-2,5
-2
-1,5
-1
-0,5
0
0,5
1
1,5
2
2,5
-0,1 00,1 0,20,3 0,40,5 0,60,7 0,80,9
Distance [Thou]
[Thou]
[mm]
Distance [mm]
S
T
-4 412202836445260
-118
-94,4
-70,8
-47,2
-23,6
0
23,6
47,2
70,8
94,4
118
-3
-2,5
-2
-1,5
-1
-0,5
0
0,5
1,5
2,5
3
-0,1 00,1 0,20,3 0,40,5 0,60,7 0,80,9 11,1 1,21,3 1,41,5 1,6
Distance [Thou]
[Thou]
[mm]
Distance [mm]
1
2
S
T
Fig. 1 Ø4 standard range Fig. 2 Ø4 extended range