User manual

© 2002 Carlo Gavazzi Industri A/S. All rights reserved 21
G 3800 X015 Configuration Software October 2002
Object Function Channel
In-/outputs
Relay output Outdoor lamp A1
Switch Light switch A1
Configuration of Master Generator
Toggle switch function Light control A1
Application Example
Task: A lamp is to be switched on and off by means of a switch.
Solution: Use for example the universal input module to provide the input signal and configure one of the
inputs for address A1. Assign the same address to one of the outputs of a relay module. Finally,
configure channel A1 in the Master Generator as a toggle switching function.
t
1
: The real-time clock activates the channel at the pre-defined time without affecting the input channel.
t
2
: By activation of the input, the output switches off directly.
t
3
: By activating the input once more, the output switches on again.
t
4
: At the set Switch off time, the input is always deactivated.
t
5
: The output can always be activated againg through the output.