Datasheet
6 Specifications ar
e subject to change without notice EM24 DIN DS 220213
EM24 DIN
Password Numeric code of max. 4
digits; 2 protection levels
o
f the programming data:
1
st level Password “0”, no
protection
2nd level Password from 1 to 9999,
all data are protected
System selection
System 3-P.n unbalanced load 3-phase (4-wire)
S
ystem 3-P unbalanced load 3-phase (3-wire)
S
ystem 3-P.1 (only AV5 and AV6)
balanced load 3-phase (3-wire) one
c
urre
nt and 3-phase to phase
voltage measurements
3-phase (4-wire) one
curr
ent and 1-phase (L1) to
neutral voltage measurement
System 2-P 2-phase (3-wire)
System 1-P 1-phase (2-wire)
Transformer ratio
VT (PT) 1.0 to 999.9 / 1000 to 6000
(only A
V5 and AV6)
CT 1.0 to 999.9 / 1000 to 9999
/ 10.00k to 60.00k (only
AV5 and AV6). The maxi-
mum power being mea-
sured cannot exceed 210
MW (calculated as maxi-
mum input voltage and
current, see the “Accuracy”
paragraph before). The
maximum VT by CT ratio is
48600. For MID complaint
applications the maximum
power being measured is
25MW.
Filter
Operating range 0 to 100% of the input dis-
play scale
Filtering coefficient 1 to 32
F
ilter action Measurements, serial output
(
fundamental variables: V, A, W
a
nd their derived ones).
Displaying Up to 3 variables per page
(see « Display pages »)
8 different set of variables
available (see « Display
pages ») according to the
application being selected
Reset By means of the front
joystick:
- dmd and dmd max;
- total energies (kWh and
kvarh) and gas/water;
- partial energies and
tariffs: kWh, kvarh
Easy connection function
AV2 and AV9 models Automatic phase sequence
detection with current and
voltage synchronisation.
AV5-AV6-AV2-AV9 models For all the display
selections, both energy
and power measurements
are independent from the
current direction. The
displayed energy is always
“imported” with the only
exception of “F” and “H”
types (see “display pages”
table). For those latter
selections the energies can
be either “imported” or
“exported” depending on
the curr
ent direction.
Software functions
Dielectric strength 4000 VRMS for 1 minute
Noise rejection CMRR 100 dB, 48 to 62 Hz
EMC According to EN62052-11
Electrostatic discharges 15kV air discharge
Immunity to irradiated Test with current: 10V/m
fr
om 80 to 2000MHz
Electromagnetic fields Test without any current:
30V/m from 80 to 2000MHz
Burst On curr
ent and voltage
measuring inputs cir
cuit:
4kV
Immunity to conducted
disturbances 10V/m from 150KHz to
80MHz
Sur
ge On current and voltage
measuring inputs circuit:
4kV; on “L” auxiliary power
supply input: 1kV
Radio fr
equency suppr
ession According to CISPR 22
Operating temperature -25°C to +55°C (-13°F to
131°F) (R.H. from 0 to 90%
non-condensing @ 40°C)
according to EN62053-21,
EN50470-1 and EN62053-
23
Storage temperature -30°C to +70°C (-22°F to
158
°F) (R.H. < 90% non-
condensing @ 40°C)
according to EN62053-21,
EN50470-1 and EN62053-
23
Installation category Cat. III (IEC60664,
EN60664)
Insulation (for 1 minute) 4000 VRMS between
measuring inputs and
power supply
4000 VRMS between power
supply and RS485/digital
output
General specifications