Datasheet
4
Carlo Gavazzi Industri A/S
CD34CNFLFxxx
CD34CNFLFxxx ENG26/08/2019
Features
Power Supply
Rated operational voltage (U
B
) 10 ... 30 VDC (ripple included)
Ripple (U
rpp
) ≤ 10%
No load supply current (I
o
) ≤ 13 mA
Power-ON delay (t
v
) < 300 ms
Outputs
Output functions NPN or PNP by sensor type
Output switching function N.O. and N.C by sensor type
Rated operational current (I
e
) ≤ 100 mA
OFF-state current(I
r
) PNP and NPN 50 μA
Voltage drop (U
d
) < 1 .5 V
Protection Short circuit, reverse polarity and transients
Utilization category
DC-1
Control of resistive loads and
solid-state loads with optical
isolation
DC-13 Control of electromagnets
Load capacitance max at (U
e
) 330 nF
Operation diagram
Tv = Power-ON delay
Power supply ON
Target Present
Break output
(N.C.)
ON
Tv
Make output
(N.O.)
ON
Tv
Response times
Operating frequency (f) ≤ 10 Hz
Response times
≤ 50 ms OFF-ON (t
ON
)
≤ 50 ms ON-OFF (t
OFF
)