User guide
Carlin part number MNEZ123 Rev. 07/13/11
– 3 –
Model EZ-1/2/3 oil burners — Instruction manual
– 3 –
Certification
EZ-1/2/3 burners are U.L.listedfor the U.S.and Canada, certiedto
complywithANSI/UL296,forusewith#1or#2heatingoil(perstandard
ASTMD396).
Burnerlabelslistcompliance,whenrequired,withspeciallocal,stateor
provincial approvals.
Install this burner in accordance with all local codes and
authoritieshavingjurisdiction.Regulationsoftheseauthori-
ties take precedence over the general instructions provided
in this manual.
United States installations
Burner/applianceinstallationsintheUnitedStatesmustcomplywiththe
latest editions of NFPA31 (Standard for theInstallationof Oil-Burning
Equipment),ANSI/NFPA70(NationalElectricalCode),and allapplicable
local codes.
Canadian installations
Burner/applianceinstallationsinCanadamustcomplywiththelatesteditions
ofCSAB139(InstallationCodeforOilBurningEquipment),CSAstandard
C22,Part1(CanadianElectricalCode),andallapplicablelocalcodes.
Codes and standards
1. EZ-1/2/3 application information
Conversion burners
General information — conversion burners
Carlin Elite burners are shipped for general distribution, with fuel units set
for 100 psig.Burnersareusuallyshippedassembled,withauniversalslip-
onange.Airtubesandhousingswillbeinstalledorshippedinseparate
boxes for field assembly.
Beforeinstallingtheburner,followguidelinesinthismanualtoensureyou
are using the correct nozzle, head-positioning bar and air tube length.
Oil nozzle selection — conversion burners
If oil nozzle selection information for the application is not available from
appliance documents, you can use Table 1, page 4, for an initial nozzle
selectionfortheapplication.Specicapplicationsmayrequiretestingmore
thanonenozzletoobtainbothcleancombustionandagoodmatchofame
shape to the combustion chamber.
OEM burners
General information — OEM burners
Eliteburnersmanufacturedforheatingappliancemanufacturers(OEM’s)
are generally identical to conversion burners (distributed through supply
houses)withoneormoreofthefollowingdifferences:
• Burnersmaybefullyassembled,withaweldedangesetattheproper
insertion depth and pitch for the appliance.
• Burnersmaybeinstalledontheapplianceorshippedinaseparate
carton.
• Burnernozzlesmaybeinstalledintheburner,baggedortiedontothe
burner chassis, or located in the appliance packaging.
• Headpositioningbarsmaybeinstalledorbaggedtotheburnerchas-
sis. Up to seven bars may be supplied. Use the bar with a range that
includes the nozzle size used.
Eliteburnerswiththe“-HP”sufxareonlysuppliedthroughtheheating
appliancemanufacturer(OEM)market.Theseburnersdifferfromstandard
modelsasfollows:
• Fuel unitpressureis factory-setbetween130 and 150 psig. Check
heating appliance manufacturer’s specifications for the correct pressure
setting.
• Theairbandscaleiscalibratedforthefuelunitpressure.Settheair
bandtomatchthenozzlesizeinstalled.Seepage11inthismanual
for further information.
Installing OEM burners
• Burnerangesareweldedtotheairtubetoensurethecorrectpitch.
Donotattempttoadjustthepitchusingtheairtubelockingscrews.
• Burnersshippedinstalledontheheatingappliancearesuppliedwith
four extra shipping screws in the air tube. These screws do not need to
be removed, and can remain in the air tube for the life of the burner.
Oil nozzle selection — OEM burners
• Useonlythenozzlespecicedintheheatingappliancemanufacturer’s
manual or burner supplement.