IAR-630-C, IAR-630-D User Manual Version 1.
Contents Hardware Overview ....................................................................................... 1 1. Interface Description .......................................................................................................... 1 2. USB Connecter Pinout ....................................................................................................... 2 3. LED Description ...........................................................................................................
WLAN User Manual Hardware Overview 1.Interface Description Item Port 1 PWR Description PWR & 15V(12~24V) DC Power Input Serial 2 Ethernet LAN-1 10/100Base-T(X),RJ45 LAN-2 10/100Base-T(X),RJ45 WAN/LAN- 10/100/1000Base-T(X), RJ45 3 3 Console PWR & RS232,115200,8,1, None Serial Reset 4 Reset Press reset button 5 seconds , then the device will restore default configure 5 DIP- Switch 6 ANT 1 W ON:WAN OFF: LAN R ON: RF Enable OFF: RF Disable D ON: DHCP Enable OFF: DHCP Disable
WLAN 模块使用手册 2.USB Connecter Pinout Pin1: +15V Pin2: UART_TxD Pin3: UART_RxD Pin4: 0V 3.LED Description LED Color Status Description PWR Green ON DC power is active Green ON WLAN is active Blinking Data is being transmitted Green ON System startup is complete Green ON LAN port link is active Blinking Data is being transmitted WLAN SYS LAN ORing Industrial Networking Corp.
WLAN 模块使用手册 Management Interface 1. Device Default Setting: IP Addesss:192168.1.1/255.255.255.0 Username: admin Password: admin 2. Over View 2.1 System Info This Page will show the System Information in detail 3 ORing Industrial Networking Corp.
WLAN 模块使用手册 2.2 LAN Info This Page will show the LAN Information in detail. 2.3 Wireless Info This Page will show the wireless Information in detail. 2.4 DHCP List This Page will show the wireless DHCP client list IP address and Mac address ORing Industrial Networking Corp.
WLAN 模块使用手册 3. Basic Setting 3.1 System Info Setting You can change the device name and click “Apply Change” button to save configuration. 3.2 WAN System provides dip switch to easily configure LAN-3 Ethernet Port from LAN to WAN mode in order to connect to outside network, you can set the WAN IP by DHCP or Static IP mode.
WLAN 模块使用手册 address Note: 1. The device default LAN-3 Port is LAN mode, WAN mode is disable. You must first set the LAN port as WAN mode by Dip Switch “W” . 3.3 LAN Label Obtain an IP address automatically Use the following IP Description Select this option if you would like to obtain an IP address automatically assigned by DHCP server in your network Select this option if you are manually assigning an IP address. address ORing Industrial Networking Corp.
WLAN 模块使用手册 Label Description DHCP Server Enable or Disable the DHCP Server function. Note: DHCP Enable/Disable is configured by DIP Switch Starting IP address: The dynamic IP assign range. Start IP address is the beginning of the dynamic IP assigns range. Maximum Number of The dynamic IP assign range. High IP address is the end of IPs: the dynamic IP assigns range.
WLAN 模块使用手册 4. Wireless Setting 4.1 AP Mode This mode provides Access Point services for other wireless clients Label Description Device Mode AP: Device plays the role of wireless Access Point Client: Device plays the role of wireless Client WDS: Device plays the role of wireless bridge Notes: The default mode is AP Mode ORing Industrial Networking Corp.
WLAN 模块使用手册 Wireless Mode HT Mode TX Data Rate Set wireless RF mode, the default setting is g/n mode Select your channel width, If you are not sure which option to use, select20/40 MHz(Auto) Set device transmit data rate This option is only adjustable when the Device plays the role of wireless AP ;If the device acts as a wireless client, it Channel follows the channel of the associated access point Notes: The Default Channel is Auto in order to make the device Scan the best free channel.
WLAN 模块使用手册 4.
WLAN 模块使用手册 5.2 Port Forwards Port Forward can allow the external device access the internal device application by device WAN IP address and TCP/UDP Number, for example: FTP, Email…. IAR-630-C LAN:IP:192.168.1.1/24 WAN:192.168.0.2/24 WAN Switch FTP://192.168.0.2:21 LAN PC IP:192.168.0.4/24 IP Camera IP:192.168.1.100/24 Gateway:192.168.1.1 11 ORing Industrial Networking Corp.
WLAN 模块使用手册 Label Description Name Set the application Name Protocol Set the data communication type TCP/UDP External Port Enter external TCP/UDP number for External device access inter IP Internal IP Set the internal device IP address address Internal Port The Application use internal TCP/UDP number Notes: As shown above Picture, the PC from external network can use ftp application which provide from IP camera 5.
WLAN 模块使用手册 Broadcast Packet Destnation: 25.255.255.0 IAR-630-C LAN:IP:192.168.1.1/24 WAN:192.168.0.2/24 WAN PC IP:192.168.0.4/24 LAN IP Camera IP:192.168.1.100/24 Gateway:192.168.1.1 Label Description Name Set the application Name Internal Port The packets used TCP/UDP number Source IP The Packets Source IP address Destination IP The Packets Destination IP address Notes: As shown above picture, the packets with Destination IP “255.255.255.
WLAN 模块使用手册 5.3 MAC Filters The device MAC filter is a policy-based filter that can allow or deny IP-based packets with Specified MAC addresses to connect the device. The device can set different policy by each SSID.
WLAN 模块使用手册 5.2 UPNP The Device support UPNP connect the Network 6. System Tools: 6.1Time Setting Label Description Timezone Set the timezone when you use NTP Server Synchronize the time System time Show the current system time ; Click Button,the device will sync time with Browser Manual setting 15 You can set the device time manually. ORing Industrial Networking Corp.
WLAN 模块使用手册 NTP Server The device also supports Synchronize the time from the NTP server. Please enter the NTP Server IP address. 6.
WLAN 模块使用手册 6.3 System Log Label Description Enable Logging provide system maintainers with real time log messages System Reboot Time The device reboot Ethernet The LAN port is connected or disconnected to a device or Link up/Down network.
WLAN 模块使用手册 6.3 Firmware Upgrade Before running a firmware upgrade, make sure the device is off-line. Click the “Browse” button to specify the firmware image file and selected “reset to default “ box, then Click “Apply changes” start the firmware upgrade. After the upgrade finished, the device will reboot itself. Attention: Please make sure the power source is stable when you upgrade your firmware. An unexpected power breakup may damage your device ORing Industrial Networking Corp.
WLAN 模块使用手册 6.4 Backup/Restore Label Description Reset to Click “Perform reset “button to reset all settings back to the factory default default values. You can also reset the hardware by pressing the reset button on the top panel of the device. Download Click“Generate archive“ button to save the configuration file backup onto your local storage media Restore Browse to specify the configuration file and click “Upload Archive”button to Backup begin importing the configuration 6.
WLAN 模块使用手册 6.4 Logout Click “Apply change” to logout current configure page ORing Industrial Networking Corp.
WLAN 模块使用手册 7. Compliance FCC Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. RF exposure warning: The equipment complies with RF exposure limits set forth for an uncontrolled environment.
WLAN 模块使用手册 and (2) this device must accept any interference, including interference that may cause undesired operation of the device. L'opération est soumise aux deux conditions suivantes: (1) cet appareil ne peut causer d'interférences,et (2) cet appareil doit accepter toute interférence, y compris celles susceptibles de provoquer fonctionnement du dispositif.