Technical data

Vario II series
Function menu
06/10
Operating manual
59
8.4 Printer initialisation
Press key to access the function menu.
Press key
as long as you arrive at the 'Printer Initialisation'
menu.
Press key
to select the menu.
Label:
Indication of label length in mm (see Technical data, on page 13).
Gap:
Indication of distance between two labels in mm
(not for continuous labels).
Minimum value: 1 mm.
Press key
to arrive at the next menu item.
Material:
Selection of the used label and transfer ribbon material.
Press key
to arrive at the next menu item.
Buzzer:
On: An acoustic signal is audible when pressing a key.
Off: No signal is audible.
Display:
Setting of display contrast.
Value range: 0 to 7.
Press key
to arrive at the next menu item.
Keyboard layout:
Selection of region for the desired keyboard layout.
The following possibilities are available: Germany, England, France,
Greece, Spain, Sweden and US.
Press key
to arrive at the next menu item.
Codepage:
Indication of the font used in the printer.
The following possibilities are available:
ANSI character set / Codepage 437 / Codepage 850 / GEM German /
GEM English / GEM French / GEM Swedish / GEM Danish
Press key
to arrive at the next menu item.
Photocell switch level:
First value = Indication of current photocell level.
Second value = Indication if a label (value = 1) or if no label (value =
0) was found.
Third value = Indication of switch level. The modification of this value
is only taken into consideration for the operating modes Photocell and
Photocell continuous.
Press key
to arrive at the next menu item.
Dispenser:
Indication of dispenser offset.
Standard value: 13 mm.
Press key
to arrive at the next menu item.
Cutter:
Indication of cutter offset.
Standard value: 23 mm.