Technical data
Technical data
Vario II series
16
Operating manual
06/10
3.1 Control inputs and outputs (option I)
Via signal outputs various operating modes of the printer can be
demanded.
The signal outputs are made available vial two 9-pin D-Sub-sockets
(Output 1) at the rear of the Control Unit. They consist of opto-
integrator semiconductor lines which are switched through res.
blocked out corresponding to the different operating modes.
In case a control output is active, then the corresponding output is to
strain with a maximum current of 30mA.
Figure 2
PIN
(socket)
Output I
Out 1: Error message
Each error status such as ribbon error is displayed.
Out 2: Print order
The printer was activated with a print order. Now print
start by IN1 is possible.
Out 3: Label generation
The printer is filled with current label data.
In case in dispensing mode either dispensing photocell
or dispensing photocell continuous is selected it is
indicated if a label is under photocell and ready to pick
up.
Out 4: Single print
The contents of printer memory is printed to the
corresponding medium by printhead.
Control outputs