Technical data

Error correction
Vario II series
104
Operating manual
06/10
The scanner could not read the
bar code within the set timeout
time.
Defective printhead.
Wrinkles in transfer ribbon.
Scanner wrong positioned.
Timeout time too short.
Check printhead.
Check transfer ribbon.
Position scanner correctly,
corresponding to the set feeding.
Select longer timeout time.
Scanner data does not
correspond to bar code data.
Check adjustment of scanner.
Check scanner settings /
connection.
Serial interface error.
Check settings for serial data
transmission as well as cable
(printer-PC).
Serial interface error. Check settings for serial data
transmission as well as cable
(printer-PC).
No printhead-FPGA data
available.
Please contact your responsible
distributor.
Error when programming
printhead-FPGA.
Please contact your responsible
distributor.
Sensor signal up is missing
(option APL 100).
Check input signals /
compressed-air supply.
Sensor signal down is missing
(option APL 100).
Check input signals /
compressed-air supply.
Sensor does not recognise a
label at vacuum plate
(option APL 100).
Check input signals /
compressed-air supply.
Print order is active but device
not ready to process it.
Check start signal.
Print data outside the defined
label.
Selection of wrong module type
(design software).
Check selected module type.
Check selection of left/right
version.