Table of water circuit, electrical and electronic spare parts, UE090 to
UE130
description spare part code position g.
UE090 UE130
Water circuit
Drain pump hose UEKDH00000 7 11.e
Manifold UEKCOLL000 6 11.e
Drain pump kit KITPSE0000 5 11.e
Internal tubing kit UEKT100XXL 3 11.e
Double check valve kit FWHDCV0000 -
Conductivity meter kit KITCN00000 4 11.e
Fill solenoid valve kit KITVC10140 2 11.e
Drain circuit UEKDC20000 1 11.e
Electrical and electronics
Display terminal HCT1EXW000 18 11.f
TAM (current transformer) UEKTAM0000 11 11.f
Contactor URKCONT300 11.f
Power transformer UEKTR20000 11 11.f
Electronic controller
(1)
HCzXxxxvi0
(2)
14 11.f
Fuse carrier URKFH20000 13 11.f
Pump control relay UEKDT00000 12 11.f
F1 - F2 power fuses UEKFUSE300 - see electrical diagram
F3 Pump fuse URKFUSE300 - see electrical diagram
F4 Transformer secondary fuse UEKFUSE400 - see electrical diagram
Connection cable between terminal and electronic controller S90CONN002 -
Tab. 11.f
(1)
To make an order specify the complete product code and the serial
number of your humidifer.
(2)
z: board version (A: basic version up to UE65;
B: with espantion board for UE90-130)
XX: kg/h (01...130)
v: voltage
i: 0 single packing; 1: multiple packing
Table of spare parts for standard and special cylinders UE090 to
UE130
Description UE090 UE130
STANDARD disposable cylinders 400V 3ph cylinder, conductivity 350 to 1250 μS/cm BL0T4C00H2 BL0T5C00H0
SPECIAL disposable cylinders 400V 3ph cylinder, conductivity 75 to 350 μS/cm BL0T4B00H2 BL0T5B00H0
SPECIAL openable cylinder 400V 3ph cylinder, conductivity 75 to 350 μS/cm BLCT4B00W2 BLCT5B00W0
400V 3ph cylinder, conductivity 350 to 1250 μS/cm BLCT4C00W2 BLCT5C00W0
Electrode and gasket kit 400V 3ph cylinder, conductivity 75 to 350 μS/cm KITBLCT4B2 KITBLCT5B2
400V 3ph cylinder, conductivity 350 to 1250 μS/cm KITBLCT4C2 KITBLCT5C2
Gasket and lter kit KITBLC4FG0 KITBLC5FG0
Tab. 11.g
11.4 Cleaning and maintenance of the cylinder
Replacement
Important: the cylinder must be only be replaced by quali ed
personnel, and with the humidi er unplugged from the power
supply.
In normal conditions, the disposable cylinders should be replaced after
one year (or 2500 hours of operation, if cleaned periodically), while the
openable cylinders last 5 years (or 10,000 hours of operation, if cleaned
periodically). They must be replaced immediately – even before the
speci ed intervals – if any anomalies occur. For example, when the lime
scale inside the cylinder prevents the correct ow of electric current.
Replacement procedure:
empty all the water (cylinder replacement procedure, see 1.
maintenance menu);
turn o the humidi er (switch “0”), and open the mains disconnect
2.
switch on the power supply (safety procedure);
wait for the humidi er and the cylinder to cool down;3.
remove the front cover;4.
disconnect the electrical cables from the cylinder and steam hose;5.
release the cylinder from the locking device and lift it to remove it;6.