6.8 Main menu
To access press PRG from the main screen
Buttons:
UP and DOWN: navigation inside the sub-menus, screens, and range
of values and settings;
ENTER: con rm and save the changes made;
ESC: to go back (pressed repeatedly returns to the “Main screen).
1. User 1. Alarm thresholds Main probe threshold
Alarm high
Alarm high
Limit probe threshold
Alarm high
Alarm delay
2. System Clock System Clock
Time
Day
Month
Year
Format
Week Day
3. Enable Scheduler Enable Enable Scheduler
Enable Scheduler On/Off
Variable Setpoint
4. Define time zone Define time zone
P1-1
P1-2
P2
P3
P4
5. Weekly scheduler Weekly scheduler
Sunday
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
6. Scheduled setp. Scheduled setpoints
Z1
Z2
Z3
Z4
2.
Installer
1. Regulation type Regulation type
Select regulation
Probe or signal type main(reg.)
Limit
Meas. units.
Cyl. Sequence
2. Probes config. Main probes config.
Min value
Max value
Offset
Limit probe config.
Min value
Max value
Offset
3. Operating options Option (1/2)
Select data view on main mask
Cylinder lifetime
warning
Lifetime limit
Alarm relay logic
Pulsed alarm relay
Options (2/2)
Delay before power-off at set
point
Dehum. control
Dehum. offset
Dehum. hyster.
Disable complete emptying for foam
4. Drainage options Drainage options (1/2)
Drain if steam request drops (quick
reg.)
Power-off electrodes when draining
Drain after inactivity time
Inactivity days
Drainage options (2/2)
Dilution drain time (standard=100)
Dilution drain freq.
(standard=100)
Additional periodic cylinder flush
Time interval
5. Water conductivity Water conductivity
Override conductivity reading
(0=no)
Conductivity limit
Warning
Alarm
6. Supervisor Supervisor connect.
Identification number for BMS
Network
Com.speed
Protocol type
Enable On/Off from supervisor
3.
Maintenance
1. Config.restore. Configuration
Save configuration
Load configuration
Normal Values
Restore default parameters
humidifier type
2. System information System information
Bios (only reading)
Boot (only reading)
Ver. (only reading)
Language
Show language mask to unit
start-up
3. Manual procedure Manual proced. Cyl.1
Manual procedure
Power contactor
Fill valve
Drain pump
Alarm
Dehumidif.
Manual proced. Cyl.2 (only 2 cyl.
versions)
Manual procedure
Power contactor
Fill valve
Drain pump
4. Change cylinder Change cylinder 1
Empty cylinder
Reset cylinder lifetime counter
Last replace (only reading)
Flush new cylinder
Change cylinder 2 (only 2 cyl.
versions)
Empty cylinder
Reset cylinder lifetime counter
Last replace (only reading)
Flush new cylinder
5. Alarm history Alarm history
Alarm (only reading)
Time (only reading)
Date (only reading)