User manual

10
GB
Wellness +030220571 - rel. 3.0 - 01.10.2007
installeruserservice
2. WATER CONNECTIONS
Important: before proceeding, disconnect the power supply.
Models UE001 to UE018 Models UE025 to UE065
Fig. 2.a
Water connections:
o
1.
install a manual valve upstream of the installation (to be able
to cut o the water supply);
o
2.
connect the humidi er to the water supply, and  t the  lter
supplied (code 98C565P016) to the inlet of the  ll solenoid
valve.. On models UE001 to UE0018, use a hose with 3/4’’G
ttings (see par. “10.2 Technical speci cations” page 37,
compatible CAREL hose: code FWH3415000). On models
UE025 to UE065 connect the hose with the non-return valve
supplied (code FWHDCV0000) to prevent the water inside the
humidi er from coming into contact with the mains water;
o
3.
install a mechanical  lter to trap any solid impurities (to be
connected downstream of the tap);
o
4
connect a section of non-conductive pipe or hose for draining
(resistant to temperatures of 100 °C and with a minimum
inside diameter of 40 mm);
o
5
prepare a funnel to interrupt continuity in the drain line;
o
6
connect a drain trap to prevent the return of bad odours
(minimum inside diameter 40 mm);
o
7
in models UE025 to UE065: connect a drain hose from the
bottom tank of the humidi er (this can run into the drain
funnel).
Important
Important: when installation is completed,  ush the supply hose
for around 30 minutes by piping water directly into the drain,
without sending it into the humidi er. This will eliminate any scale or
processing residues that may block the drain pump and cause foam
when boiling.
Fittings provided for the water connections:
Models UE001 to UE018 Models UE025 to UE065
Key:
A.
supply water inlet
B.
drain water outlet
C.
bottom tank drain water outlet (models UE025
to UE065 only)
Fig. 2.b