User manual

38
GB
Wellness +030220571 - rel. 3.0 - 01.10.2007
installeruserservice
10.4 Models of concentrated jet steam distributors
UEW model
code
UE001W
UE003W
UE005W
UE008W
UE009W
UE010W
UE015W
UE018W
UE025W
UE035W
UE045W
UE065W
steam outlet dia. (mm) 22 22 30 30 30 30 30 30 40 40 40 2x40
max. capacity (kg/h) 1/1.5358910151825354565
CAREL SD steam distributors
code steam inlet dia. (mm) max. capacity kg/h
SDPOEM0012 22/30 3 1 1 --------- -
SDPOEM0022 30 18 11111111- - - -
SDPOEM0000 30 18 (with 30 mm opening) 11111111(2)*(2)*(4)**(4)**
Tab. 10.d
1 = the humidi er is connected to just one distributor
(2) = the humidi er is connected to two distributors (using the Y” kit: UEKY000000)
2 = the humidi er is  tted with two outlets and can be connected to two distributors
(4) = the humidi er is  tted with two outlets and can be connected to up to four distributors (using two “Y kits)
* = use CAREL “Y kit code UEKY000000 (40 mm inlet and 2 x 30 mm outlets)
** = use CAREL “Y kit code UEKY000000 (40 mm inlet and 2 x 30 mm outlets)
10.5 Models of linear distributors
UEW model
code
UE001W
UE003W
UE005W
UE008W
UE009W
UE010W
UE015W
UE018W
UE025W
UE035W
UE045W
UE065W
steam outlet dia.
(mm)
22 22 30 30 30 30 30 30 40 40 40 2x40
max. capacity kg/h1/1.5358910151825354565
CAREL DP linear distributors
code steam inlet
dia. (mm)
max. capacity kg/h length in mm
DP035D22R0 22 4 332 1 1 - - - ------ -
DP045D22R0 22 6 438 1 1 - - - ------ -
DP060D22R0 22 9 597 1 1 - - - ------ -
DP085D22R0 22 9 835 1 1 - - - ------ -
DP035D30R0 30 5 343 - - 1 - - ------ -
DP045D30R0 30 8 427 - - 1 1 - ------ -
DP060D30R0 30 12 596 - - 1 1 1 1 ----- -
DP085D30R0 30 18 850 - - 1 1 1 1 1 1 (2)* - - -
DP105D30R0 30 18 1048 - - 1 11111(2)*- - -
DP125D30R0 30 18 1245 - - 1 11111(2)*- - -
DP085D40R0 40 25 834 - - - -----1(2)**(2)**(4)**
DP105D40R0 40 35 1015 - - - -----11(2)**2
DP125D40R0 40 45 1222 - - - -----1112
DP165D40R0 40 45 1636 - - - ------112
DP205D40R0 40 45 2025 - - - ------11-
Tab. 10.e
1 = the humidi er is connected to just one distributor
(2) = the humidi er is connected to two distributors (using the Y” kit: UEKY000000) or UEKY000400)
2 = the humidi er is  tted with two outlets and can be connected to two linear distributors
(4) = the humidi er is  tted with two outlets and can be connected to up to four linear distributors (using two “Y kits)
* = use CAREL “Y kit code UEKY000000 (40 mm inlet and 2 x 30 mm outlets)
** = use CAREL “Y kit code UEKY40400 (40 mm inlet and 2 x 30 mm outlets)
CAREL reserves the right modify or change its products without prior warning.