Table of water circuit, electrical and electronic spare parts, UE001
to 018
spare part code position gure
UE001 UE003 UE005 UE008 UE009 UE010 UE015 UE018
Water circuit
Fill tank + conductivity meter UEKVASC000 1 8.a
Fill solenoid valve kit KITVC10006 KITVC10011 3 8.a
Internal pipe kit UEKT10000S UEKT10000M 2 8.a e 8.c
Plastic humidi er base 18C565A019 16 8.b
Plastic humidi er top 18C476A011 7 8.b
Assembled f/d manifold + pump 18C565A018 3 8.a
Electrical and electronics
Display terminal HCT1EWF000 11 8.b
TAM (current transformer) 09C565A042 8 8.b e 8.d
Contactor 0203012AXX 0203013AXX
Power transformer: 230-400/24-24 V 09C565A016 9 8.b e 8.d
Microprocessor electronic controller HCA0EW0000 13 8.b e 8.d
pCOe expansion board (Controller I/O
expansion)
PCOE00TLN0 12 8.b
Fuse carrier 0606192AXX 11 8.b e 8.d
F1 - F2 230 to 400 Vac power fuses 0605321ALG - see wiring diagrams
F4 Transformer secondary fuse (F41) 0605581AXX (F41)
0605620AXX (F42)
- see wiring diagrams
F5 - F6 pCOe fuse 0605615AXX -
AP1 - AP2 Terminal fuse 0605595AXX - see wiring diagrams
Connection cable between terminal and
electronic controller
S90CONN002 -
PF1 Controller fuse 0605604AXX - see wiring diagrams
Tab. 8.a
Table of spare part codes, single-phase cylinders UE001 to 005,
electrode and gasket kit
Model UE001 UE003 UE005 UE009
STANDARD disposable cylinders 200/230 Vac 3~, conductivity 350 to 1250 μS/cm BL0S1F00H1 BL0S1F00H1 BL0S2F00H0 BL0S3F00H0
SPECIAL disposable cylinders 200/230 Vac 3~, conductivity 125 to 350 μS/cm BL0S1E00H1 BL0S1E00H1 BL0S2E00H0 BL0S3E00H0
SPECIAL openable cylinders 200/230 Vac 3~, conductivity 125 to 350 μS/cm BLCS1E00W1 BLCS1E00W1 BLCS2E00W0 BLCS3E00W0
200/230 Vac 3~, conductivity 350 to 1250 μS/cm BLCS1F00W1 BLCS1F00W1 BLCS2F00W0 BLCS3F00W0
Electrode and gasket kit 200/230 Vac 3~, conductivity 125 to 350 μS/cm KITBLCS1E0 KITBLCS2E0 KITBLCS2E0 KITBLCS3E0
200/230 Vac 3~, conductivity 350 to 1250 μS/cm KITBLCS1F0 KITBLCS2F0 KITBLCS2F0 KITBLCS3F0
Electrode gasket kit KITBLC1FG0 KITBLC2FG0 KITBLC2FG0 KITBLC3FG0
Tab. 8.b
Table of spare part codes, three-phase cylinders UE003 to 018,
electrode and gasket kit
Model UE003 UE005 UE008 UE010 UE015 UE018
STANDARD
disposable
cylinders
200/230 VAC 3~, conductivity 350 to 1250
μS/cm
BL0T1B00H1 BL0T2B00H0 BL0T2B00H0 BL0T3B00H0 BL0T3A00H0 BL0T3B00H0
400 VAC 3~, conductivity 350 to 750 μS/cm BL0T1C00H1 BL0T2C00H0 BL0T2C00H0 BL0T3C00H0 BL0T3B00H0 BL0T3B00H0
SPECIAL
disposable
cylinders
200/230 VAC 3~, conductivity 125..350 μS/cm BL0T1A00H1 BL0T2A00H1 BL0T2A00H1 BL0T3A00H1 BL0T3A00H1 BL0T3A00H1
400 VAC 3~, conductivity 125 to 350 μS/cm BL0T1A00H1 BL0T2B00H0 BL0T2B00H0 BL0T3B00H0 BL0T3B00H0 BL0T3B00H0
400 VAC 3~, conductivity 750 to 1250 μS/cm BL0T1D00H1 BL0T2D00H0 BL0T2D00H0 BL0T3D00H0 BL0T3D00H0 BL0T3D00H0
SPECIAL
openable
cylinders
200/230 VAC 3~, conductivity 125..350 μS/cm BLCT1A00W1 BLCT2A00W1 BLCT2A00W1 BLCT3A00W1 BLCT3A00W1 BLCT3A00W1
400 VAC 3~, conductivity 125 to 350 μS/cm BLCT1A00W1 BLCT2B00W0 BLCT2B00W0 BLCT3B00W0 BLCT3B00W0 BLCT3B00W0
400 VAC 3~, conductivity 350 to 750 μS/cm BLCT1C00W1 BLCT2C00W0 BLCT2C00W0 BLCT3C00W0 BLCT3B00W0 BLCT3B00W0
400 VAC 3~, conductivity 750 to 1250 μS/cm BLCT1D00W1 BLCT2D00W0 BLCT2D00W0 BLCT3D00W0 BLCT3D00W0 BLCT3D00W0
Electrode and
gasket kit
Electrode kit 200/230 Vac 3~, 125/350 μS/cm KITBLCT1A0 KITBLCT2A0 KITBLCT2A0 KITBLCT3A0 KITBLCT3A0 KITBLCT3A0
Electrode kit 200/230 Vac 3~, 350/1250 μS/cm KITBLCT1B0 KITBLCT2B0 KITBLCT2B0 KITBLCT3B0 KITBLCT3B0 KITBLCT3B0
Electrode kit 400 Vac 3~, 125/350 μS/cm KITBLCT1A0 KITBLCT2B0 KITBLCT2B0 KITBLCT3B0 KITBLCT3B0 KITBLCT3B0
Electrode kit 400 Vac 3~, 350/750 μS/cm KITBLCT1C0 KITBLCT2C0 KITBLCT2C0 KITBLCT3C0 KITBLCT3C0 KITBLCT3C0
Electrode kit 400 Vac 3~, 750/1250 μS/cm KITBLCT1D0 KITBLCT2D0 KITBLCT2D0 KITBLCT3D0 KITBLCT3D0 KITBLCT3D0
Electrode gasket kit KITBLC1FG0 KITBLC2FG0 KITBLC2FG0 KITBLC3FG0 KITBLC3FG0 KITBLC3FG0
Tab. 8.c