User manual

19
GB
Wellness +030220571 - rel. 3.0 - 01.10.2007
installeruserservice
“ON/OFF quick access” screen
Fig. 6.d
Used to:
enable steam production (ON) and activate the manual drain function
(*);
select the type of essence (1, 2, 3);
enable the sanitisation function (ON);
switch on the light (ON).
Function buttons:
ENTER: move the cursor inside the screen;
UP or DOWN: enable/disable.
(*) Manually drain the water in the cylinder:
access the “ON/OFF quick access” screen,
position the cursor on steam”;
press the UP and DOWN buttons together for a few seconds.
The same procedure can be repeated to stop the drain cycle in progress.
Important:
the “ON/OFF quick access” screen only displays the functions enabled
in con guration phase.
with steam production disabled (OFF) the supply and exhaust fans can
be enabled manually;
if the humidi er is enabled but not producing steam, check the
following possible causes:
possible cause solution
the temperature of the steam bath is
higher than the set point
wait for the temperature of the
bath to fall below the set point
alarms are active that stop steam
production (ALARM button  ashing).
check and resolve the error (see
par. “7.13” page 26)
The humidi er is set to “manual” deactivate the manual procedure
(submenu par. “7.12”, see page 25)
time bands are active (CLOCK icon
ashing on the display);
disable the time band (see par.
“7.5“ page 22), or modify as
required.
Tab. 6.a
Alarms” screen
Fig. 6.e
Indicates an alarm is active, press to display.
“Management menu screen
Fig. 6.f
To access press:
PRG from the “Main screen;
ENTER to move the cursor to the “0”;
UP or DOWN to enter the password “77”;
ENTER to con rm and enter the management submenu:
User;
Essence;
Fan management;
Maintenance (info, software, hardware);
Sanitisation;
Alarm log;
Network;
GSM.
The management menu, the submenu and the screens are cyclical, and
follow the same path also in the opposite direction.
1.
2.
3.
4.
5.
6.
7.
8.