6. STARTING AND USER INTERFACE
Before starting the humidi er, check:
water connections: Fig. 2.a page 10. In the event of water leaks do not
start the humidi er before having resolved the problem;
steam distribution: Fig. 3.d page 13;
electrical connections chap. “4” page 14.
6.1 Starting
1
1
0
ON
2 if the cylinder is new, run a pre-wash cycle (the cylinder is  lled and
emptied three times, cleaning the inside walls from impurities, see
par. “7.12” page 25).
6.2 Stopping
1 empty the water in the cylinder to avoid stagnation (manual drain by
“ON/OFF quick access” screen, see the following page, or par. “7.15”
page 27);
2
1
0
OFF
6.3 User interface
1
4
5
6
2
3
Fig. 6.a
Key to the keypad:
button function
1
alarm list active alarms
2
PRG access the “Management menu” screen (password
= 77)
3
ESC return to “Simple” or “Main screen
4
UP increase the set point
5
ENTER from “Main screen: open “ON/OFF quick access”
screen
from “Simple screen: select type of essence
ENTER and PRG: move from “Simple” to “Main” screen
(and vice-versa).
6
DOWN decrease the set point
The humidi er produces steam when the temperature recorded
(displayed in the centre of the screen in large characters) is less than the
set point (at the top in smaller characters).
Set point: maximum temperature threshold above which the humidi er
no longer produces steam (can be changed using the UP and DOWN
buttons).
To display the temperature inside the steam bath and the set point, two
types of screens are available:
o
o
o
“Simple”: with the possibility to modify the set point and the type of
essences;
“Main”: with the possibility to modify the set point, the type of essences
and access the “ON/OFF quick access” and “Management menu” screens.
“Simple” screen
Fig. 6.b
Key :
symbol function
1 day and month
2 set point temperature (can be modi ed using the UP or
DOWN button)
3 temperature inside the steam bath (measured by the
probe/probes)
4 hour and minutes
5 time bands set (when  ashing indicates that a time
band is in progress)
6 light on inside the steam bath
Essence (e.g.
Mint)
essence enabled (delivered when the humidi er
produces steam)
“Main screen
Fig. 6.c
Key :
symbol function
1 set point temperature (can be modi ed using the UP or
DOWN button)
2 temperature inside the steam bath (measured by the
probe/probes)
3 light on inside the steam bath
4 time bands set (when  ashing indicates that a time
band is in progress)
5 steam production (without cloud steam production in
standby)
6 supply fan (fan 1) on
7 exhaust fan (fan 2) on to
8 when moving indicates the operation of the fans, when
still indicates fans enabled but in standby
Essence (e.g.
Mint)
essence enabled (delivered when the humidi er
produces steam)
The following screens can be accessed from the “Main” screen:
ENTER button: “ON/OFF quick access”
PRG button: “Con guration menu”.