User manual
18
GB
“Wellness” +030220571 - rel. 3.0 - 01.10.2007
installeruserservice
6. STARTING AND USER INTERFACE
Before starting the humidi er, check:
water connections: Fig. 2.a page 10. In the event of water leaks do not
start the humidi er before having resolved the problem;
steam distribution: Fig. 3.d page 13;
electrical connections chap. “4” page 14.
6.1 Starting
1
1
0
ON
2 if the cylinder is new, run a pre-wash cycle (the cylinder is lled and
emptied three times, cleaning the inside walls from impurities, see
par. “7.12” page 25).
6.2 Stopping
1 empty the water in the cylinder to avoid stagnation (manual drain by
“ON/OFF quick access” screen, see the following page, or par. “7.15”
page 27);
2
1
0
OFF
6.3 User interface
1
4
5
6
2
3
Fig. 6.a
Key to the keypad:
button function
1
alarm list active alarms
2
PRG access the “Management menu” screen (password
= 77)
3
ESC return to “Simple” or “Main” screen
4
UP increase the set point
5
ENTER from “Main” screen: open “ON/OFF quick access”
screen
from “Simple” screen: select type of essence
ENTER and PRG: move from “Simple” to “Main” screen
(and vice-versa).
6
DOWN decrease the set point
The humidi er produces steam when the temperature recorded
(displayed in the centre of the screen in large characters) is less than the
set point (at the top in smaller characters).
Set point: maximum temperature threshold above which the humidi er
no longer produces steam (can be changed using the UP and DOWN
buttons).
To display the temperature inside the steam bath and the set point, two
types of screens are available:
o
o
o
“Simple”: with the possibility to modify the set point and the type of
essences;
“Main”: with the possibility to modify the set point, the type of essences
and access the “ON/OFF quick access” and “Management menu” screens.
“Simple” screen
Fig. 6.b
Key :
symbol function
1 day and month
2 set point temperature (can be modi ed using the UP or
DOWN button)
3 temperature inside the steam bath (measured by the
probe/probes)
4 hour and minutes
5 time bands set (when ashing indicates that a time
band is in progress)
6 light on inside the steam bath
Essence (e.g.
Mint)
essence enabled (delivered when the humidi er
produces steam)
“Main” screen
Fig. 6.c
Key :
symbol function
1 set point temperature (can be modi ed using the UP or
DOWN button)
2 temperature inside the steam bath (measured by the
probe/probes)
3 light on inside the steam bath
4 time bands set (when ashing indicates that a time
band is in progress)
5 steam production (without “cloud” steam production in
standby)
6 supply fan (fan 1) on
7 exhaust fan (fan 2) on to
8 when moving indicates the operation of the fans, when
still indicates fans enabled but in standby
Essence (e.g.
Mint)
essence enabled (delivered when the humidi er
produces steam)
The following screens can be accessed from the “Main” screen:
ENTER button: “ON/OFF quick access”
PRG button: “Con guration menu”.
•
•