User manual

14
GB
Wellness +030220571 - rel. 3.0 - 01.10.2007
installeruserservice
4. ELECTRICAL CONNECTIONS
4.1 Preparing the electric cableways
Models UE001 to UE018
outside unit, bottom view inside unit, top view
Fig. 4.a
Models UE025 to UE065
outside unit, side view
3
2
1
Fig. 4.b
Key to Figs. 4.a and 4.b:
1.
power cable inlet;
2.
utility cable inlet (after having drilled the plastic part): sanitisation
pump, essences, fans, light.
3.
probe cable inlet. On models UE001 to UE018, remove the plastic tab
and use it to secure the cable (held in place by the screws provided).
4.2 Power cable connection
Single-phase models Three-phase models
humiSt
eam
Wellness
AP2
AP1
GND
L
N
humiSt
eam
Wellness
AP2
AP1
GND
L1
L2 L3
Fig. 4.c (view inside unit, electrical compartment)
Important
Important: connect the yellow-green cable to the earth point
(GND).
4.3 Temperature probe connection (M2.1-
M2.8)
the humidi er can be connected to up to two probes for measuring
and controlling the temperature inside the steam bath. The connection
with two probes allows an average” temperature reading (with the
possibility to attribute a di erent “weight to each probe, see par. “7.3
Temperature probes”, page 21);
active probes (voltage or current signal, CAREL code: ASET030001) or
NTC probes (variable resistance) can be connected.
For connection, use the eight pin” connection kit (supplied in the
packaging) and run the cables out of the humidi er through the cable
opening” (Figs. 4.a or 4.b).
Active CAREL probe connections:
OUT T
GND
+G
OUT T
GND
+G
1 2
3
M.2 M.7 M.8
M.2.1
M.2.2 M.2.3 M2.4 M.2.5 M.2.6 M.2.7 M.2.8
Fig. 4.d (detail of electronic board, humidi er electrical compartment)