8. ALARMS
code display and
symbol
var. code
I89
meaning causes solution reset
(press)
alarm
relay
activation
e ect red LED
signal on
board (*)
(if terminal not
connected)
E0 - 1008Hex calibration
parameter software
veri cation errora
internal memory error if the problem persists,
contact the CAREL service
center
-- yes humidi cation
stopped
3 fast  ashes
E1 - 1004Hex parameter
con guration error
error in the
parameters user
if the problem persists,
contact the CAREL service
center
-- yes humidi cation
stopped
4 fast  ashes
EH
1010Hex excess current
over-current at the
electrodes;
probable electrode
malfunction
or
water conductivity
temporarily too high
(especially when
starting after a short
stop)
1. check the operation of the
drain pump
2. check the seal of the
ll electrovalve when not
energised
3. drain part of the water
and re-start
AUTO yes humidi cation
stopped
2 fast  ashes
EP 1020Hex no production
excessive reduction
in production , or
cylinder completely
depleted or water
Perform maintenance on
the cylinder
ESC yes humidi cation
stopped
4 slow  ashes
CY
3001Hex cylinder life pre-
alarm
the cylinder full limit
of 1500 h (default)
perform maintenance and/
or replace the cylinder
ESC
(the alarm is
reactivated
after 50 hrs)
no signal only 7 fast  ashes
EF 2004Hex no water
Check:
water supply and  ll
valve;
whether the manual drain
is open;
blockage of the  lter on
the  ll solenoid valve;
whether there is excessive
backpressure in steam
outlet, preventing the
ow of water into the
cylinder by gravity;
that the steam outlet
hose is not choked or that
there are no pockets of
condensate;
that the power cables
are connected to the
cylinder
automatic
(after 10
minute
waiting
time)
yes
(in 10
minute
waiting
time)
humidi cation
stopped for 10
minutes only
3 slow  ashes
Ed
2008Hex failed drain
check the drain pump and
drain connection
ESC yes humidi cation
stopped
5 slow  ashes
CP
3004Hex cylinder being
depleted signal
cylinder life ending, perform
maintenance and/or replace
the cylinder
AUTO no signal only 6 slow  ashes
CL 3008Hex cylinder depleted
signal
cylinder life ended, perform
maintenance and/or replace
the cylinder
AUTO no signal only 10 slow
ashes
EA
3002Hex foam
excessive foam in
the cylinder during
boiling.
the formation of
foam is generally
due to the presence
of surfactants in the
water (lubricants,
solvents, detergents,
water treatment
agents, softeners)
or an excessive
concentration of
dissolved salts.
1. drain the water supply
lines
2. clean the cylinder
3. check for the presence of
softeners
(in this case, use another
type of water
or reduce the softening)
ESC no signal only 9 slow  ashes
E2 3010Hex memory backup fails
internal memory error if the problem persists,
contact the CAREL service
center
-- no signal only 6 fast  ashes
Mn
1001Hex end of cylinder life
the cylinder has exceeded
the limit of 2000 hours,
replace the cylinder
reset hour
counter
yes humidi cation
stopped
8 fast  ashes