humiSteam Basic Addendum manual
ENG WARNINGS damage of any kind whatsoever, whether contractual, extra-contractual or due to negligence, or any other liabilities deriving from the installation, use or impossibility to use the product, even if CAREL or its subsidiaries are warned of the possibility of such damage. The CAREL humidifiers are advanced products, whose operation is specified in the technical documentation supplied with the product or can be downloaded, even prior to purchase, from the website www.carel.com.
ENG 4. ELECTRICAL CONNECTIONS 4.2 Power cable connection Before making the connections, ensure that the machine is disconnected from the mains power supply. Check that the power supply voltage of the appliance corresponds to the value indicated on the rating plate inside the electrical panel. Insert the power and ground connection cables into the electrical panel compartment using the tear-proof cable gland supplied, or through the cable gland with cable stop, and connect the ends to the terminals (see Fig.
ENG Table of water circuit, electrical and electronic spare parts, UE001 to UE018 UE001 spare part code UE005 UE008 UE009 UE003 UE010 UE015 UE018 position fig. 9 9.b Electrical and electronics Power transformer: 460/24 V UEKTR30000 Tab. 9.a (1) when ordering, as well as the controller code specify the complete code and serial number of the humidifier. (2) xx: kg/h ( 01,......
ENG 9.5 Cylinder connection, three-phase models UE025 to UE065 conductivity (μS/cm) production (kg/h) 25 power supply (V) 460 B B B B B B B B 75/350 μS/cm 350/1250 μS/cm 75/350 μS/cm 350/1250 μS/cm 75/350 μS/cm 350/1250 μS/cm 75/350 μS/cm 350/1250 μS/cm 35 45 65 Tab. 9.f The cable ends must be tightened with the top nut to 3 Newton • m ( 27 lbf-in). (units with BL*T5* cylinder only) A B 2 3 3 1 3 D C E 2 F F C A B A 2 1 3 E D B 1 1 2 Fig. 9.
ENG 10. WIRING DIAGRAMS 10.3 Diagram of three-phase models UE003 to UE018 (460V) key: TB K F1-F2 F3 F4 TR MS FV DP LS CS TAM terminal block contactor primary fuses fuse protection drain pump secondary fuse transformer manual switch fill valve drain pump high level electrodes conductivity meter external TAM Fig. 10.a (**) Important: for the TAM configuration and connection see par. 11.1 7 “UE BASIC” +0300043EN - rel. 1.
ENG 10.5 Diagram of three-phase models UE025 and UE065 (460V) key: TB K F1-F2 F3 F4 TR MS FV DP LS CS TAM Fig. 10.c (**) Important: for the TAM configuration and connection see par. 11.1 “UE BASIC” +0300043EN - rel. 1.
ENG 11. GENERAL FEATURES AND MODELS The following table lists the electrical data relating to the power supply of the various models and the specifications of each. Note that some models may be powered at different voltages, obviously with different power input and steam production. model UE003 UE005 UE008 UE010 UE015 UE018 UE025 UE035 UE045 UE065 (1) (2) (3) (4) (5) steam production (2; 4) (kg/h) (lbs/hr) 3,0 / 6.6 5,0 / 11.0 8,0 / 17.6 10,0 / 22.0 15,0 / 33.0 18 / 39.7 25 / 55.1 35 / 77.2 45 / 99.
CAREL INDUSTRIES HQs Via dell’Industria, 11 - 35020 Brugine - Padova (Italy) Tel. (+39) 049.9716611 - Fax (+39) 049.9716600 e-mail: carel@carel.com - www.carel.com “UE BASIC” +0300043EN - rel. 1.