User`s manual

Intel-GE Care Innovations™ QuietCare® System
Hardware Maintenance Guide
Document: DHF-3756 Page 49 of 60
Revision: 1.0 Effective: January 29, 2012
5. Press S3 to continue.
6. To delete the sensor, press S3 a second time.
7. To add/replace the sensor, press S2, which will
bring you to this screen:
8. Have your battery handy. Press S2.
9. When the “Searching” screen appears, press
the 9v battery into the battery slot.
10. When the base unit picks up the sensor the
screen will appear.
11. When this screen appears, press S5.
12. When adding or replacing the sensor is
completed, press S5 to scroll through all the
sensor screens, until you come to the “More
Sensors?” screen. Press S3 if there are no more
sensors to add, press S5 to see more sensors.
When S3 is pressed, the following screen will
prompt a summary.
Press S5 to continue to the following screen.
13. Whenever you add or replace a sensor, do a
Walkaround test (sensor check). Press S2 to
begin. (See appropriate section in main part of
manual.)
CheckingSensorConfigurationonaQuietCareDialUpSystem
A sensor configuration check should be performed any time a maintenance activity is performed in a residence
to ensure the sensors are operating correctly.
Complete the following steps:
1. Power up the Base station.
2. Pull the AC adapter jack out of the base
station, wait a few seconds, then plug it
back in.
3. When the unit begins the countdown, press
S6 twice - to go directly into Walkaround
Test mode.
4. Walk past the sensors, making sure the
green light blinks as you walk by. If the
system is operating correctly, as you walk
by each sensor, the letter corresponding to it
will appear on the base station LCD screen.