User`s manual

Intel-GE Care Innovations™ QuietCare® System
Hardware Maintenance Guide
Page 48 of 60 Document: DHF-3756
Revision: 1.0 Effective: January 29, 2012
For the Night Motion feature, sensors are placed in the residence in such a manner as to detect the resident
while out of bed and moving around the apartment at night, while not detecting movement in the bed or
sleeping chair.
To install the Night Motion feature:
- The Bedroom sensor should be installed such that it could not detect motion of the resident on the
bed, but can detect motion in the area just off the bed.
o As a general rule, place sensor about 8 inches – 12 inches off side of bed, to avoid detecting
motion of resident in bed, which can lead to false-positive Night Motion alerts.
o Since the sensors cannot detect motion above the top lens of the sensor, installing the sensor
horizontally may be best.
- If the resident could exit the bed on two sides, an extra sensor may need to be added to detect that
side of the bed. Use another sensor with the bedroom role as the second sensor if possible.
The sensor positioning guidelines described in this document also apply to Night Motion installations, with the
exception of detecting motion on the bed.
In some instances, it may not be possible to install sensors for Night Motion without breaking one of these
installation rules. If this will be the case, check with your installations manager before you proceed.
Adding and Replacing Sensors
This section describes the process for adding a sensor (for example, a primary bathroom has two exits instead
of one) or replacing a malfunctioning sensor. In rare circumstances, you might need to delete a sensor.
When replacing a sensor, place it back in the same location as the defective or missing sensor. If you cannot
determine the original position, find a location that meets the sensor positioning guidelines.
AddingandReplacingQuietCareDialUpSensors
Call 1-855-885-CARE or email at support@careinnovations.com to obtain guidance on how to add or replace
QuietCare — Dial-Up sensors. The customer support agent may ask you to confirm the base station ID on the
back of the base station matches the # programmed in the base station. Then the customer support agent
may walk you through the following steps:
NOTE: If you are adding a “Bedroom 2”, or “Near Door 2” sensor to a QuietCare — Dial-Up system, be sure
that the base station has downloaded the latest version of the operating script so that these sensor
slots are available.
DO NOT register sensors to the following slots; Front Door, Mattress, Chair Pad.
1. Make sure that the battery has been removed
from or has not yet been installed in the sensor.
You will also need to complete this step if
replacing a sensor.
2. Remove the power cord from the base unit, then
plug it back in. While the base unit is counting
down from 14-0, press S6, followed by S5, to
get to the following screen. (Must do this before
countdown is completed)
3. Press S5 to scroll through this screen.
4. Keep pressing S5 until you reach the sensor
letter you wish to add or replace