Specifications
7
CALIBRATION, Cont.
DECIMAL POINT
Press the NET key to show the current setting. Then press the ON/ZERO key to
select the desired value:
0=XXXX 1=XXX.X
2=XX.XX 3=X.XXX
Press the NET key to save.
CAPACITY
Press the NET key to show the current capacity setting. Then press the ON/ZERO
key to advance the flashing digit from 0 through 9 (200.
0). Select the value then
press the TARE key to advance to the next digit location (20
0.0). Repeat the
process until the capacity has been entered. Press the NET key to save.
WEIGHING UNITS
Press the NET key to show the current setting. Then press the ON/ZERO key to
select the desired value: 1-2 where 1=Pounds Only and 2=Kilograms Only. Press
the NET key to save it.
(Please note, although selection 3 will display and can be selected, it is
INVALID
for the HSDC scale.)
CALIBRATION WEIGHT
Press the NET key to show the current calibration weight. Then press the ON/
ZERO key to advance the flashing digit of calibration weight from 0 through 9
(150.
0). Select the value then press the TARE key to advance to the next digit
location (15
0.0). Repeat the process until the calibration weight has been
entered. Place this amount of calibration test weights on the scale, then press the
NET key. The display will show ---- then:
Remove the test weights and press the NET key. The display will show ----
then proceed to the next prompt.
ZERO TRACKING RANGE
Press the NET key to show the current division setting. Values of 0 through 9 and
0.5 are valid for the zero tracking range. Press the ON/ZERO key to step through
and select 0.5 as the division value, then press the NET key to save. If a zero
tracking range division of 0 through 9 is desired, first press the ON/ZERO key to
select 0, then press the TARE key to advance to the next digit location and press
the ON/ZERO key to select 0 through 9 divisions. Press the NET key to save.
4% ZERO TRACKING LIMIT
Press the NET key to show the current setting. Then press the ON/ZERO key to
toggle between yes and no. YES=4% limit, no=100% limit. Press the NET key to
save. (NOTE: 4% limit is for Canadian use)
POWER UP ZERO
Press the NET key to show the current setting. Then press the ON/ZERO key to
toggle between yes and no. YES=enable, no=disable. Press the NET key to save.
FILTERING
Press the NET key to show the current level of filtering. Then press the ON/ZERO
key to select the desired value:
0=no filtering 1=minimal filtering
2=moderate filtering 3=custom filtering
Press the NET key to save setting.
If you select level 3 then:
Press NET to show current filter weight setting. Press ON/ZERO to select filter
weight level (1 through 99,-99 being the greatest filtering and 1 the least). Press
the NET key to save setting.
CAP=
dPP=
FLt=
Unt=
Lod=
UnLod
trA=
trL=
PUO=
F=