Specifications
2
OFF
GROSS
G
TARE
T
NET
N
ON
ZERO
0
Model Capacity Graduation
HSDC-200 200 lb 200 x 0.1 lb
HSDC-100 100 lb 99.95 x 0.05 lb
HSDC-40 40 lb 40 x 0.02 lb
HSDC-20 20 lb 20 x 0.01 lb
HSDC-500 500 lb 500 x 0.2 lb
HSDC-100KG 100 kg 99.95 x 0.05 kg
HSDC-40KG 40 kg 40 x 0.02 kg
HSDC-20KG 20 kg 20 x 0.01 kg
SPECIFICATIONS, Cont.
BATTERY INSTALLATION
Before weighing operations can begin it will be necessary to install the batteries in the HSDC
hanging scale. This same procedure should also be followed when battery replacement becomes
necessary. Make certain that only “C” size alkaline batteries are used as replacements.
NOTE! Exposure of batteries to high temperatures (above 140
° F) will decrease
their capacity resulting in shorter operation time.
Step 1
Using a screwdriver, remove the two retaining screws from the back of the instrument. Remove the
battery compartment cover.
Step 2
Remove the old batteries, if present. Insert six new “C” cells making certain that each cell is
correctly positioned. Refer to the next diagram for proper battery placement.
Battery Compartment
Cover
Remove these screws