Specifications

3
).34!,,!4)/.#ONT
0OWER3UPPLY
1. Plug power supply into a wall receptacle that supplies 115 VAC power and into the
connector on the underside of the chassis.
2. On models requiring 230 VAC power, use the Cardinal/Detecto model 8529-B216-08,
230 VAC power supply. After installation of the proper connection, plug scale power
supply into 230 VAC receptacle.
#!54)/.4OAVOIDELECTRICALHAZARDANDSEVEREDAMAGETOTHESCALEUSE
ONLYTHEWALLPLUGINPOWERMODULEPROVIDEDWITHTHESCALE
3. START-UP - The scale is equipped with ON and OFF keys on the keypad. When the
/. key is pushed, the scale will show zero weight, signalling that the scale is ready for
use. If the deadload on the scale is not within ± 4% of the deadload used during
calibration, the scale will display "74 (LoAd) or =1074 (UnLoAd), indicating that
weight must be added or removed, respectively, from the platform. Once the deadload
is within ± 4% of the deadload used during calibration, the scale will zero and is ready
for use.
+%9&5.#4)/.3
This section describes the use of each of the keys on the Price Computing Scale.
4HEMEMBRANEKEYBOARDISNOTTOBEOPERATEDWITHPOINTEDOBJECTSPENCILS
PENSFINGERNAILSETC$AMAGETOKEYBOARDRESULTINGFROMTHISPRACTICEWILL
NOTBECOVEREDUNDERWARRANTY
Pressing this key when the scale is off will apply power to the instrument.
This key is used to remove power from the scale, turning it off. Press and hold
the /&&key for one or two seconds to completely remove power from the scale.