Specifications

7
OPERATION (cont.)
Tare operation for known tare (container) weight
Note: Known tare weights must be entered as numbers compatible with the particular scale division.
Example: 30 lb x 0.01 = increments of 0.01 - 15 kg x 0.005 increments of 0.005. Any known tare
entry not compatible with particular scale counting increments will be replaced and scale will display
-int-. Press CLEAR key and re-enter correct compatible number.
lb Models
1. Key in known tare weight, up to 4 digits (ignoring the decimal point), as a number appearing
in the unit price display.
2. Press TARE key. Entry will move to the weight display and be shown as negative (-) weight.
Net indicator will illuminate.
3. Place container and commodity on scale. Net weight of commodity will be displayed. Enter
unit price and proceed with price-computing operation.
4. After known tare operation is complete, tare weight will clear automatically after a positive
weight is indicated, unit price has been entered and commodity is removed from scale.
5. When the weight is at c/z (center of zero), any tare can be cleared by pushing the CLEAR
key.
Note: Automatic tare clear is inoperable when scale is in the PREPACK mode.
kg Models
1. Key in known tare weight, up to 4 digits, as a number appearing in the unit price display
(ignore decimal point). Example:
Key in 0.28 kg as 2-8-0 Key in 1.00 kg as 1-0-0-0
Key in 0.095 kg as 9-5 Key in 1.2 kg as 1-2-0-0
2. Press TARE key. The acceptable tare entry will move to the weight display and be shown as
negative(-) weight. Example: a tare entry of 1.50 kg should appear in the unit price display as
15.00. After the TARE key is pressed, the weight disply will show - 1.500 and Net indicator
will illuminate.
3. After known tare operation is complete, tare weight will automatically clear after a positive
weight is indicated, unit price has been entered and commodity is removed from scale.
Note: Automatic tare clear is inoperable when scale is in the PREPACK mode.
Prepack (PPK) Operation
For repetitive price-computing of commodities with the same unit price:
1. Enter tare if so desired as outlined in Tare Operation. Tare entry will be retained in
PREPACK mode.
2. Enter unit price and press PREPACK key. PREPACK mode indicator PPK will illuminate.
3. Place commodities on scale and proceed with operation.
4. When prepacking operation is ended, press CLEAR key to clear unit price and turn off
PREPACK mode. Tare will then clear automatically.
Note: After PREPACK mode is entered, no change of unit price can be made until PREPACK mode
is cancelled.