Specifications

9
WEIGHT
SETUP AND CALIBRATION PRIOCEDURE (cont.)
3a.LoAd = If recalibration is not desired, press 0 (zero) then ENTER and proceed to step five.
3b. If recalibration is desired, apply a weight equal to 70%-100% of the scale capacity to the scale
(do not use fractional lb or kg weights). Select the value of the weight and press ENTER.
4. UnLd= Remove the weight from the scale and press ENTER to proceed.
5. UPdP= Enter number of decimal places in the unit price; 0,1,2, or 3 (does not affect preset
prices) and press ENTER.
6. tPdP= Enter number of decimal places in the total price; 0,1,2, or 3 and press ENTER.
7. rnd5= Enter 1 (Yes) to round total price to nearest 5, 0 (No) for normal operation and press
ENTER.
8. tPbL= Enter 1 (Yes) to enable total price blanking when scale motion is present, 0 (No) to
disable and press ENTER.
9. FrAC= Enter 0, 1, or 2 and press ENTER.
0 = Fraction keys are disabled in lb mode or only 250 kg in kg mode.
1 = Enables both fraction keys (lb or kg mode).
2 = Disables both fraction keys (lb or kg mode).
UNIT PRICE $
2
UPdP=
TOTAL PRICE $
lb
100g
250g
kg
P
E
R
PPK
ZERO
NET
WEIGHT UNIT PRICE $
2
tPdP=
TOTAL PRICE $
lb
100g
250g
kg
P
E
R
PPK
ZERO
NET
WEIGHT UNIT PRICE $
30
LoAd=
TOTAL PRICE $
lb
100g
250g
kg
P
E
R
PPK
ZERO
NET
WEIGHT UNIT PRICE $
UnLd
TOTAL PRICE $
lb
100g
250g
kg
P
E
R
PPK
ZERO
NET
PrESS
EntEr
WEIGHT UNIT PRICE $
0
rndS=
TOTAL PRICE $
lb
100g
250g
kg
P
E
R
PPK
ZERO
NET
WEIGHT UNIT PRICE $
0
tPbL=
TOTAL PRICE $
lb
100g
250g
kg
P
E
R
PPK
ZERO
NET
WEIGHT UNIT PRICE $
0
FrAC=
TOTAL PRICE $
lb
100g
250g
kg
P
E
R
PPK
ZERO
NET