Instruction manual
8526-M256-O1 Rev B • CS Series
21
RS232 AND SERIAL PRINTER SETUP, CONT.
9:` – Communication Protocol Setting
1. With the WEIGHT display showing 9:` (with the 1 flashing), use the
alphanumeric keypad to enter 0 and 2.
2. The WEIGHT display will change to 9:` with the 2 flashing.
3. Press the MC key.
4. The PIECE WEIGHT display will change to show the current setting.
5. If the setting displayed is acceptable, press the MC key to save it.
6. Otherwise, using the numeric keys, enter the desired setting for the Communication
Protocol and press the MC key to save it. Available values are 00 through 02.
`
= N, 8, 1
`
= E,7, 1
`
= O, 7, 1
9:` – Output Data Format Setting
1. With the WEIGHT display showing 9:` (with the 2 flashing), use the
alphanumeric keypad to enter 0 and 3.
2. The WEIGHT display will change to 9:` with the 3 flashing.
3. Press the MC key.
4. The PIECE WEIGHT display will change to show the current setting.
5. If the setting displayed is acceptable, press the MC key to save it.
6. Otherwise, using the numeric keys, enter the desired setting for the Output Data
Format and press the MC key to save it. Available values are 00 through 07.
`
= Fixed format 1 (details on the next page)
`
= Fixed format 2 (details on the next page)
`
= Reserved
`
= Same as screen display (general format)
`
= Same as screen display (simple format)
`
= Gross weight (general format)
`
= Net weight (general format)
`
= Tare (general format)